HP StorageWorks MSA2312fc HP StorageWorks 2000 Modular Smart Array G2 cable co - Page 8
Two servers connected to an MSA2000i G2 enclosure, MSA2000i G2 expansion configurations
View all HP StorageWorks MSA2312fc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Two servers connected to an MSA2000i G2 enclosure Two servers/dual path requires four (4) Ethernet cables. MSA2000i G2 expansion configurations Connecting to an MSA2000 3.5" 12-drive enclosure A: Connecting an MSA2000i G2 single-controller array enclosure to an MSA2000 3.5" 12-drive enclosure with a single I/O module requires one (1) mini-SAS to SAS cable. A + B: Connecting an MSA2000i G2 dual-controller array enclosure to an MSA2000 3.5" 12-drive enclosure with dual I/O modules requires two (2) mini-SAS to SAS cables. Connecting to an MSA70 drive enclosure A: Connecting an MSA2000i G2 single-controller array enclosure to an MSA70 drive enclosure with a single I/O module requires one (1) mini-SAS to mini-SAS cable. A + B: Connecting an MSA2000i G2 dual-controller array enclosure to an MSA70 drive enclosure with dual I/O modules requires two (2) mini-SAS to mini-SAS cables. Connecting to multiple MSA2000 3.5" 12-drive enclosures In this example, connecting an MSA2000i G2 array enclosure to three MSA2000 3.5" 12-drive enclosures requires two (2) mini-SAS to SAS cables and four (4) HP Ext. SAS cables. Page 8