Verifying SAN connectivity, From the MSA CLI, enter

Page 11 highlights

Verifying SAN connectivity Step Description Check 1 For switch fabric SAN connectivity: F • Log on to the switch management utility and verify that the switch fabric is set up properly, including zoning. • From the MSA CLI, enter show this_controller to verify that this MSA array controller is configured for switch fabric connectivity. • From the MSA CLI, enter show other_controller to verify that the other MSA array controller is configured for switch fabric connectivity. Example display: CLI>show this_controller Controller MSA1500(c) Hewlett-Packard P56350A9IMN01Z Version 6.32 Build 1 Hardware 7 Component Enclosure. Controller Identifier: NODE_ID = 500508B3-00909AA0 SCSI_VERSION = SCSI-3 Supported Redundancy Mode:Active/Standby Asym-Active/Active Current Redundancy Mode:Asym-Active/Active Active/Standby Simulation DISABLED Device Port SCSI address 7 Terminal speed for the CLI is set to 19200. Host Port_1: REPORTED PORT_ID 500508B3-00909AA9 PORT_1_TOPOLOGY = F_Port (Switch Fabric Enabled) 2 For direct connect SAN connectivity: F From the MSA CLI of the newly added controller: • Enter show this_controller_hard_address to determine if the MSA array controller is configured for direct connect SAN connectivity. • Enter set this_controller_hard_address to enable hard addressing on the array controller. Example display when hard addressing is disabled: CLI>show this_controller_hard_address Hard Addressing is disabled. Example display of enabling a hard address: CLI>set this_controller_hard_address enable 10 Hard Addressing is enabled. Loop ID=10, AL-PA=0xD5 Negotiated Two Gig Migrating from an active/passive single controller to active/active dual controllers in HP-UX environments 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Migrating from an active/passive single controller to active/active dual controllers in HP-UX environments
11
Verifying SAN connectivity
Step
Description
Check
1
For switch fabric SAN connectivity:
Log on to the switch management utility and verify that the switch fabric is set up
properly, including zoning.
From the MSA CLI, enter
show this_controller
to verify that this MSA array
controller is configured for switch fabric connectivity.
From the MSA CLI, enter
show other_controller
to verify that the other MSA
array controller is configured for switch fabric connectivity.
Example display:
CLI>show this_controller
Controller
MSA1500(c) Hewlett-Packard P56350A9IMN01Z Version 6.32 Build 1
Hardware 7
Component Enclosure.
Controller Identifier:
NODE_ID = 500508B3-00909AA0
SCSI_VERSION = SCSI-3
Supported Redundancy Mode:Active/Standby Asym-Active/Active
Current Redundancy Mode:Asym-Active/Active Active/Standby
Simulation DISABLED
Device Port SCSI address 7
Terminal speed for the CLI is set to 19200.
Host Port_1:
REPORTED PORT_ID 500508B3-00909AA9
PORT_1_TOPOLOGY = F_Port
(Switch Fabric Enabled)
2
For direct connect SAN connectivity:
From the MSA CLI of the newly added controller:
Enter
show this_controller_hard_address
to determine if the MSA array
controller is configured for direct connect SAN connectivity.
Enter
set this_controller_hard_address to
enable hard addressing on
the array controller.
Example display when hard addressing is disabled:
CLI>show this_controller_hard_address
Hard Addressing is disabled.
Example display of enabling a hard address:
CLI>set this_controller_hard_address enable 10
Hard Addressing is enabled.
Loop ID=10, AL-PA=0xD5
Negotiated Two Gig