HP Surestore 1200ex Optical Drive and Library SCSI-2 Command Reference - Page 338
FRU Isolation Test, Calibrate Magazines, Clear Magazine Min, Calibrate Mailslot, Clear Mailslot Max
View all HP Surestore 1200ex manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 338 highlights
Autochanger Error Codes Autochanger Error Codes Jukebox Micro-Move Error Codes Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY) No. Test Name 60 FRU Isolation Test 65 Calibrate Magazines 66 Clear Magazine Min/ Max 67 Calibrate Mailslot 68 Clear Mailslot Max/ Min 75 UPS Test Description Assumes that something has physically failed, either electronic or mechanical. A series of special low-level tests are executed to select the three (or fewer) FRUs which are most likely to be at fault. Tests 30, 31, 33, 35, 36, 40, and 50 are executed as a part of the isolation process. Calculates a min/max clearance for a magazine. (The selected magazine should be empty.) The autochanger requires a disk in the mailslot. The test passes if clearance is 85 encoder counts (1 mm) up and down. (See Info 23 for actual values.) If this test is run by SCSI command, set Byte 1 to the magazine number. The test returns: PASS or FAIL. Clears the value calculated in Test 65. Calculates a min/max clearance for the mailslot. The autochanger requires a disk in the mailslot. The test passes if clearance is 85 encoder counts (1 mm) up and down. (See Info 23 for actual values.) The test returns: PASS or FAIL. Clears the value calculated in Test 67. Tests whether or not the UPS is connected properly. The test returns PASS if connected properly, FAIL if the UPS is not connected properly or if there is no UPS connected. Appendix B B-51