HP Surestore 15 Slot with DLT7000 Digital Linear Tape SCSI-2 Drive and SCSI-3 - Page 187
Sense Key, Additional Sense Code (ASC), SKSV, Error Code, Bit Pointer, Field Pointer
View all HP Surestore 15 Slot with DLT7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 187 highlights
NOTE Library SCSI-3 Command Set Log Sense Command (4DH) Sense Key See Table 3-1 on page 3-3. Additional Sense Code (ASC) The Additional Sense Code specifies detailed information related to the error reported in the Sense Key field. See Table 3-2 on page 3-4. Additional Sense Code Qualifier (ASCQ) The Additional Sense Code specifies detailed information related to the error reported in the Sense Key field. See Table 3-2 on page 3-4. SKSV When set to 1, the Sense Key Specific bytes contains valid data. When set to 0: C/D 1 = Illegal Parameter is in Command Descriptor Block. 0 = Illegal Parameter is in Data Out Phase. BPV 1 = Bit pointer field is valid. 0 = Bit pointer field is invalid. Bit Pointer Specifies which bit is in error. When a multiple bit field is in error, the pointer points to the most significant bit in the field. Field Pointer Specifies which byte is in error. Bytes are numbered starting from 0. When a multiple-byte field is in error, the pointer points to the most significant byte of the field. Bytes identified as being in error are not necessarily the bytes that need to be changed to correct the problem. Error Code Determined by fault isolation, this error code indicates the cause of the failure. The values of the hardware error codes are in Table 3-4 on page 3-16. Chapter 2 2- 143