HP Surestore Disk Array 12h HP SureStore E Disk Array FC60 Service Manual (A56 - Page 226
Spin down Failed Drives, Restart LUN binding, LUN 0 created, Enable Mode Select commands, Controller
![]() |
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 226 highlights
24. Spin down Failed Drives: Drives that are marked Failed, are now spun down, and their Fault LEDs are lighted. 25. Restart LUN binding: The controller will discover and restart LUNs that were in the process of being bound when the reset or power fail occurred. 26. LUN 0 created: If no LUNs are discovered, a default LUN is created. 27. Enable Mode Select commands: The controller will now enable Mode Select commands, allowing users to make configuration changes, such as adding or deleting LUNs, changing controller modes, or drive states. 28. Controller Start-Of-Day completed. 226 Controller Enclosure Troubleshooting
![](/manual_guide/products/hewlettpackard-surestore-disk-array-12h-hp-surestore-e-disk-array-fc60-service-manual-a5635a-92620e9/226.png)
226
Controller Enclosure Troubleshooting
24.
Spin down Failed Drives:
Drives that are marked Failed, are now spun down, and
their Fault LEDs are lighted.
25.
Restart LUN binding:
The controller will discover and restart LUNs that were in the
process of being bound when the reset or power fail occurred.
26.
LUN 0 created:
If no LUNs are discovered, a default LUN is created.
27.
Enable Mode Select commands:
The controller will now enable Mode Select
commands, allowing users to make configuration changes, such as adding or deleting
LUNs, changing controller modes, or drive states.
28.
Controller
Start-Of-Day completed.