HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 206
Verifying Disk Array Connection, On Windows NT and Windows 2000, On HP-UX
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 206 highlights
Verifying Disk Array Connection On Windows NT and Windows 2000 The HP Storage Manager 60 software is used to verify that the disk array is visible to the Windows host. See the HP Storage Manager 60 User's Guide for instructions on installing and using the HP Storage Manager 60 software. On HP-UX To verify that the Disk Array FC60 is visible to the HP-UX host, run an ioscan by typing the following: ioscan -fn An output will be displayed similar to that in Figure 79. The sample ioscan shown in the figure includes entries for both disk array controllers: one at loop ID 6, and the other at loop ID 7 (loop IDs are determined by the Fibre Channel Host ID switch setting on the back of the controller enclosure). The virtual SCSI bus entries for both controllers are also shown. Note The State of the each controller and its associated LUNs should be CLAIMED. Any other condition indicates that the host is having difficulty accessing the controller. If the State is not CLAIMED, refer to "Troubleshooting" on page 359 for help in identifying the problem. 206 Verifying Disk Array Connection