HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 Dual-Hop - Page 37
Per-Priority Flow Control commands
View all HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Per-Priority Flow Control commands Make sure PFC (Per-priority Flow Control - 802.1Qbb) is enabled on the interface connected to VC. Flow Control must be disabled. PFC ensures the lossless behavior of the FCoE traffic. Check the status of Flow Control; it must be turned off on interfaces connected to Virtual Connect. o show interface ethernet 1/5 flowcontrol Check the status of the PFC. It must be turned on on interfaces connected to Virtual Connect. o show interface ethernet 1/5 priority-flow-control If the command shows "Mode" as Off or On, it should be changed to Auto. To force PFC mode Auto on an interface, enter: interface ethernet 1/5 priority-flow-control mode auto If the command shows "Mode" as Auto and "Oper" as Off or if the command returns nothing, you should check the setup of the Shared Uplink Set in VCM by making sure that an associated FCoE Network has been properly defined. 37