HP XM600 hp kayak xm600 series 2, service handbook for minitower models
HP XM600 - Kayak - 128 MB RAM Manual
View all HP XM600 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP XM600 manual content summary:
- HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 1
HP Kayak PC Workstation Service Handbook PC Workstations and Accessories 4th Edition June 2000 - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 2
5 HP Kayak XM600 Minitower PC Workstations Models and Accessories Product Cache Number1 Memory Std. RAM Hard Drive Video Controller Multi-media LAN HP Kayak XM600 7/xxx PC Workstation HP Kayak XM600 500 MHz - 100 FSB2 (CPL: 01/2000 ) D9533N and D9533T D9534N and D9534T Pentium III with 512 - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 3
Workstations Product Cache Number1 Memory Std. RAM Hard Drive Video Controller Multi-media LAN HP Kayak XM600 600 MHz - 133 MHz FSB (CPL:01/2000 ) D9540N and D9540T D9544N and D9544T Pentium III with i256 KB of L2 cache memory 128 MB SDRAM 100 MHz non-ECC 9.1 GB 7.2 krpm SCSI 128 MB RDRAM - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 4
HP Kayak XM600 Minitower PC Workstations Product Cache Number1 Memory Std. RAM Hard Drive Video Controller Multi-media LAN HP Kayak XM600 733 MHz - 133 FSB (CPL:01/2000 ) D8366N and D8366T D9539N and D9539T Pentium III with i256 KB of L2 cache memory D9565N3 and D9565T 128 MB RDRAM non-ECC - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 5
memory 128 MB RDRAM non-ECC 9.1 GB 7.2 krpm SCSI Matrox Millennium G400-Dual 16 MB video memory fitted 48! IDE CD-ROM 1HP 10/100 BT PCI All models are supplied with a 1.44 MB Floppy Disk Drive, an integrated IDE controller, and an integrated audio chip on the system board. HP Kayak XM600 - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 6
HP Kayak XM600 Minitower PC Workstations Supported Accessories Memory Upgrades RDRAM 64 MB non-ECC main memory RDRAM 128 MB non-ECC main memory RDRAM 256 MB non-ECC main memory RDRAM 64 MB ECC main memory RDRAM 128 MB ECC main memory RDRAM 256 MB ECC main memory D9500A D9502A D9503A D9504A D9506A - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 7
1. All models shipped with SDRAM memory should be converted to RDRAM memory. Consult HP Support for further information. 2. Dual Processor Kits include: processor, voltage regulator module and heatsink. 3. NIC = Network Internet Connector 5-6 HP Kayak XM600 Minitower PC Workstations Minitower PC - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 8
HP Kayak XM600 Minitower PC Workstations System Board Connectors, BIOS, and Memory Mouse (upper) & Keyboard (lower) Two USB Serial Port A Serial Port B (Both ports are stacked with the Parallel Port) Midi & Audio AGP PRO PCI 1 PCI 2 PCI 3 PCI 4 PCI 5 Processor 1 Connector CPU FAN 1 Processor 2 - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 9
. 8 OFF Retains CMOS memory. Clears CMOS memory at next boot. 9 OFF Enables User and System Administrator passwords. Clears the passwords at next boot. 5 10 ON Selects the chassis type. ON = Minitower. OFF = Desktop. NOTE: A limited number of early HP Kayak XM600 system boards have 20 - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 10
a Dual Processor / Replacing a Processor HP Kayak XM600 Desktop PC Workstations are supplied with a Pentium III processor and an integrated VRM (Voltage Regulator Module) on the system board. A separate VRM is not required. Single processor models can be upgraded to dual processor systems by - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 11
HP Kayak XM600 Minitower PC Workstations The SDRAM Memory Expansion Card socket always contains a "RDRAM Terminator Module". Second RIMM module, or RDRAM Continuity Module if unused RDRAM Terminator Module First RIMM module Processor 2, or processor terminator card if unused Processor 1 System - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 12
the metal plate from the chassis. Insert the guide rail labeled "L" on the left-hand side (cable connectors facing towards you and positioned at the top), and the guide rail "R" on the righthand side of the hard disk drive. Minitower PC Workstations HP Kayak XM600 Minitower PC Workstations 5-11 - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 13
HP Kayak XM600 Minitower PC Workstations Parts and Part Numbers 4 5 1a 8 7 5 6 3 2a 2b 1d 1 1b 2d 1c 2c 5-12 HP Kayak XM600 Minitower PC Workstations Minitower PC Workstations - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 14
Memory Expansion Card 7 RDRAM Continuity Module 8 RDRAM Termination Module 5064-9764 - 5184-1501 - 5183-9401 - 5182-1857 - See system board parts list 0950-3628 - 5064-9725 - 5064-0480 - D8660-63001 - 5065-1281 - Minitower PC Workstations HP Kayak XM600 Minitower PC Workstations - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 15
should be converted to RDRAM memory. Consult HP Support for further information. 2. For optional disk drive information, refer to the Accessory Service Handbook. 3. Should only be used in conjunction with an Elsa Synergy II AGP video card for dual monitor display. 5-14 HP Kayak XM600 Minitower PC - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 16
SDRAM memory should be converted to RDRAM memory. Consult HP Support for further information. Manuals and Documentation Description User's Guide - English only Part Number D8369-90001 Troubleshooting Guide Technical Reference Manual Online documentation can be downloaded from: http://www.hp.com - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 17
HP Kayak XM600 Minitower PC Workstations Notes 5 5-16 HP Kayak XM600 Minitower PC Workstations Minitower PC Workstations - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 18
If an error occurs during the POST, which prevents the PC Workstation from starting, and before the display device has been initialized, a series of beep codes are issued. Beep codes indicate that a fatal error has occurred and can be reported one after another if there is more than one detected - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 19
A Beep Codes for the HP Kayak XU800 Number of Beeps 1 2 3 4 5 6 7 8 Description The memory refresh circuitry is faulty. Parity error in the base memory (the first 64 KB block) of memory. Memory error. Clock error. Processor test error. Input/Output (I/O) error. The processor on the system board - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 20
replace the system board. Perform the following actions in this order: 1 Press F2 to enter the Setup program, then F9 to load the default BIOS settings. 2 Clear the CMOS. 3 Flash the BIOS. If the error still occurs, replace the system board. Replace the processor(s). Beep, POST, and Error Codes A-3 - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 21
/HP reseller that system board is defective. This can be caused by problems with the ROM on integrated video, an add-on video board or the ROM on a SCSI card. Inform reseller for the affected component. 1. Non-HP memory modules are not supported. Only HP memory modules should be used. A-4 Beep - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 22
are for all models before the HP Kayak XU800 and XM600 PC Workstations. Beep Pattern Beep Code 1-2-2-3 1-3-1-1 1-3-1-3 1-3-3-1 1-4-4-1 1-3-4-1 1-3-4-3 2-1-2-3 2-2-3-1 1-2 1 4-2-4-4 Numeric Code 16h 20h 22h 28h 30h 2Ch 2Eh 46h 58h 98h B4h / F4h Description BIOS ROM check-sum failure DRAM - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 23
A POST and Error Codes Notes A-6 Beep, POST, and Error Codes - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 24
floppy disk, then flashes the BIOS. However, it should be noted that during the flash process, the screen remains blank. MaxiLife will display a message on the LCD panel "RECOVERY MODE". 10 The recovery process is finished when there are four beeps. 11 Power off the PC Workstation. Remove the floppy - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 25
disk. The latest system BIOS (standard flash operation) can be downloaded from HP's Support Web site at: http://www.hp.com/go/kayaksupport. Then select HP Kayak XM600 PC Workstation. Instructions on updating the BIOS are supplied with the downloaded BIOS files and a BIOS flash utility (flash.txt - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 26
BIOS flash, Switch 9 (XA models) or 10 (XW and XA-s models) Down Position WARNING: WARNING: For Kayak XU Series 03xx, XA-s Series B 02xx and XA Series 05xx, a specific there is a much longer beep (approximately around 1 to 2 minutes). 7 Power off the computer. Press the power ON/OFF button (for - HP XM600 | hp kayak xm600 series 2, service handbook for minitower models - Page 27
Notes B B-4 Recovery Boot Active Procedures
HP Kayak
PC Workstation
Service Handbook
PC Workstations and
Accessories
4th Edition
June 2000