HP XP20000/XP24000 HP StorageWorks XP24000/XP20000 SNMP Agent Reference Guide - Page 36

Alert Level, Description, Trap Reference Code, SIM13, SNMP Failure Trap Reference

Page 36 highlights

Table 18 SNMP Failure Trap Reference Codes (continued) Trap Reference Code SIM22 SIM23 SIM13 46 2y xx 46 3y xx 46 5y xx 49 0x xx AC 50 xy BF 0x A5 BF 0x A6 BF 1x 1x BF 2x 1x BF 4x 1x BF 41 A5 BF 41 A6 BF 5x 1x BF 5x Bx BF 58 xx BF 60 D0 BF 60 D1 BF 6A xx BF 7x 1x BF 8x Ax BF E3 A2 BF 22 xx BF 48 xx BF 4C xx BF 78 xx BF 79 xx 74 Others 7B 00 03 7C 03 00 7F F4 0x 7F F5 0x Description Dynamic sparing normal end Dynamic sparing abnormal end Dynamic sparing warning end Sidefile 40% over HDU power supply shutdown detected Power supply (DKU) Fuse failure Environmental failure Fuse failure Abnormal temperature Alarm for voltage Power supply (DKC) Warning for power supply Warning of power supply box Power supply Warning of power supply box Warning for battery Battery Warning for battery Warning for battery Battery Warning for alternating current DKC environment (3 phase AC Box) Warning for alternating current (DKU AC Power supply Box) (DKU) Abnormal fan Fan (DKC) Warning caused by remaining a jumper DKC environment socket Error in two-SVP configuration SVP error AC-DC alarm Power supply (DKU) 56V Low voltage HDD-PL 37V Low voltage Abnormal fan Fan fuse blow Sub-SVP error Router failure Router failure Audit log FTP transfer failed SVP failure Virus detected (Cleaning finished) Virus detected (Virus isolated) Alert Level SERVICE MODERATE SERVICE SERVICE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE SERVICE MODERATE 36 SNMP Failure Trap Reference

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

Table 18 SNMP Failure Trap Reference Codes
(continued)
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
SERVICE
Dynamic sparing normal end
xx
2y
46
MODERATE
Dynamic sparing abnormal end
xx
3y
46
SERVICE
Dynamic sparing warning end
xx
5y
46
SERVICE
Sidefile 40% over
xx
0x
49
MODERATE
Power supply
(DKU)
HDU power supply shutdown detected
xy
50
AC
MODERATE
Environmental
failure
Fuse failure
A5
0x
BF
MODERATE
Fuse failure
A6
0x
BF
MODERATE
Abnormal temperature
1x
1x
BF
MODERATE
Power supply
(DKC)
Alarm for voltage
1x
2x
BF
MODERATE
Warning for power supply
1x
4x
BF
MODERATE
Power supply
Warning of power supply box
A5
41
BF
MODERATE
Warning of power supply box
A6
41
BF
MODERATE
Battery
Warning for battery
1x
5x
BF
MODERATE
Warning for battery
Bx
5x
BF
MODERATE
Battery
Warning for battery
xx
58
BF
MODERATE
DKC environment
Warning for alternating current
D0
60
BF
MODERATE
(3 phase AC Box)
D1
60
BF
MODERATE
Power supply
(DKU)
Warning for alternating current (DKU AC
Box)
xx
6A
BF
MODERATE
Fan (DKC)
Abnormal fan
1x
7x
BF
MODERATE
DKC environment
Warning caused by remaining a jumper
socket
Ax
8x
BF
MODERATE
SVP error
Error in two-SVP configuration
A2
E3
BF
MODERATE
Power supply
(DKU)
AC-DC alarm
xx
22
BF
MODERATE
HDD-PL
56V Low voltage
xx
48
BF
MODERATE
37V Low voltage
xx
4C
BF
MODERATE
Abnormal fan
xx
78
BF
MODERATE
Fan fuse blow
xx
79
BF
MODERATE
Sub-SVP error
Others
74
MODERATE
Router failure
Router failure
03
00
7B
MODERATE
SVP failure
Audit log FTP transfer failed
00
03
7C
SERVICE
Virus detected (Cleaning finished)
0x
F4
7F
MODERATE
Virus detected (Virus isolated)
0x
F5
7F
36
SNMP Failure Trap Reference