HP rp7400 Site Preprepation - rp7400 - Page 17

Specify the System Requirements

Page 17 highlights

Table 3 Specify the System Requirements System Electrical Specifications Description Specification AC Input Voltage Rangea 200 to 240 VAC AC Input Line frequency 50 to 60 Hz AC Input Current 18 A (max load at 200 VAC)12 A (max load at 240 VAC) AC Inrush Current TBD AC Input Power 1250 VA maximum Power Supply Output Rating 1163 watts DC continuous Holdup without system reset 25ms at 50/60Hz (1 cycle, or 500ms) Battery Backup Time 15 minutes With optional external PowerTrust UPS. Without the optional UPS there is no battery backup. a. The power supply auto-ranges to the AC voltage and frequency. It does not have to be reconfigured to operate over its rated operating ranges. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

17
Specify the System Requirements
System Electrical Specifications
Table 3
Description
Specification
AC Input Voltage Range
a
200 to 240 VAC
AC Input Line frequency
50 to 60 Hz
AC Input Current
18 A (max load at 200 VAC)12 A (max load at 240
VAC)
AC Inrush Current
TBD
AC Input Power
1250 VA maximum
Power Supply Output
Rating
1163 watts DC continuous
Holdup without system
reset
25ms at 50/60Hz (1 cycle, or 500ms)
Battery Backup Time
15 minutes
With optional external PowerTrust UPS. Without
the optional UPS there is no battery backup.
a. The power supply auto-ranges to the AC voltage and frequency. It does
not have to be reconfigured to operate over its rated operating ranges.