HP t620 Hardware Reference Guide - Page 38

Specifications, Appendix

Page 38 highlights

A Specifications For the latest specifications or additional specifications on the HP t620 Thin Client or the HP t620 PLUS Thin Client, go to http://www.hp.com/go/ quickspecs/ and search for your specific model to find the model-specific QuickSpecs. Dimensions Width: HP t620 Thin Client Width: HP t620 PLUS Thin Client 40 mm 65 mm 1.57 in. 2.56 in. Depth 240 mm 9.45 in Height (without stand) 219.70 mm 8.65 In Height (with stand) 220 mm 8.66 in. Temperature Range (fanless design)* Operating** 10°C to 40°C 50°F to 104°F With the fiber NIC is installed 10°C to 35°C 50°F to 95°F (max. rate of change is 10°C per hour or 18°F per hour) Nonoperating -30°C to 60°C -22°F to 140°F (max. rate of change is 20°C per hour or 36°F per hour) *Specifications are at sea level with altitude derating of 1°C/300 m (1.8°F/1000 ft) to a maximum of 3 Km (10,000 ft), with no direct, sustained sunlight. Upper limit may be limited by the type and number of options installed. ** The operating temperature range when the thin client is attached to a flat panel using the HP Quick Release is 10°C to 35°C (50°F to 95°F). Relative Humidity (non-condensing) Operating 10% to 90% (max. wet bulb temperature is 28°C or 84.2°F) Nonoperating 5% to 95% (max. wet bulb temperature is 38.7°C or 101.6°F) 32 Appendix A Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53

A
Specifications
For the latest specifications or additional specifications on the HP t620 Thin Client or the HP t620
PLUS Thin Client, go to
go/ quickspecs/
and search for your specific model to find
the model-specific QuickSpecs.
Dimensions
Width: HP t620 Thin Client
Width: HP t620 PLUS Thin Client
Depth
Height (without stand)
Height (with stand)
40 mm
65 mm
240 mm
219.70 mm
220 mm
1.57 in.
2.56 in.
9.45 in
8.65 In
8.66 in.
Temperature Range
(fanless design)*
Operating**
With the fiber NIC is installed
(max. rate of change is 10°C per hour or 18°F per hour)
Nonoperating
(max. rate of change is 20°C per hour or 36°F per hour)
10°C to 40°C
10°C to 35°C
-30°C to 60°C
50°F to 104°F
50°F to 95°F
-22°F to 140°F
*Specifications are at sea level with altitude derating of
1°C/300 m (1.8°F/1000 ft) to a maximum of 3 Km (10,000
ft), with no direct, sustained sunlight. Upper limit may be
limited by the type and number of options installed.
** The operating temperature range when the thin
client is attached to a flat panel using the HP Quick
Release is 10°C to 35°C (50°F to 95°F).
Relative Humidity
(non-condensing)
Operating
(max. wet bulb temperature is 28°C or 84.2°F)
Nonoperating
(max. wet bulb temperature is 38.7°C or 101.6°F)
10% to 90%
5% to 95%
32
Appendix A
Specifications