Hitachi C10RB Instruction Manual - Page 17

English, Table Extension Scale Pointer Fig. P, Fig. P, Adjusting Cam Locking Lever Fig. Q, Fig. Q

Page 17 highlights

TABLE EXTENSION SCALE POINTER (FIG. P) The table extension scale pointer (1) should be at 13 inches on the scale when the extension is in the closed position. If not, loosen the holding screw (2), position the pointer over 13 inches and re-tighten the screw. Fig. P 1 13 2 ADJUSTING CAM LOCKING LEVER (FIG. Q) If the extension table moves when it is open and locked, then the cam locking lever (1) may be loose and need adjustment, therefore, adjustment to the cam locking lever is necessary. To adjust the locking lever tension, turn the bar (2) with a 10 mm wrench until it is tightened, but do not over tighten. Fig. Q 1 2 English - 17 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

– 17 –
English
TABLE EXTENSION SCALE POINTER (FIG. P)
The table extension scale pointer (1) should be at 13
inches on the scale when the extension is in the closed
position. If not, loosen the holding screw (2), position
the pointer over 13 inches and re-tighten the screw.
Fig. P
ADJUSTING CAM LOCKING LEVER (FIG. Q)
If the extension table moves when it is open and locked,
then the cam locking lever (1) may be loose and need
adjustment, therefore, adjustment to the cam locking
lever is necessary. To adjust the locking lever tension,
turn the bar (2) with a 10 mm wrench until it is tightened,
but do not over tighten.
Fig. Q
1
2
1
2
13