VIDEO RGB SEARCH ASPECT AUTO BLANK Operating MAGNIFY ON HOME PAGE UP VOLUME Adjusting the position OFF END PAGE DOWN MUTE 1. Press the POSITION button on the remote control. The "POSITION" indication will appear on the screen. FREEZE MY BUTTON KEYSTONE 1 2 2. Use the cursor buttons to adjust the picture position. POSITION MENU ENTER When you want to reset the operation, press the RESET button on the remote ESC RESET control during the operation. To complete this operation, press the POSITION button again. Even if you do not do anything, the dialog will automatically disappear after a few seconds. ● When this function is performed on a video signal, s-video signal or component video signal, some image such as an extra-line may appear at outside of the picture. ● When this function is performed on a video signal, s-video signal, or component video signal of 525i (480i) or 625i (576i), the range of this adjustment depends on the OVER SCAN in IMAGE menu (28) setting. It is not possible to adjust when the OVER SCAN is set to 10. VIDEO RGB SEARCH Correcting the keystone distortions ASPECT AUTO BLANK 1. Press the KEYSTONE button on the remote control. A dialog will appear on the -';5610' #761':'%76' screen to aid you in correcting the distortion. /#07#.   2. Use the cursor buttons ▲/▼ to select AUTO or MANUAL operation, and press the button ► to perform the following. 1) AUTO executes automatic vertical keystone correction. 2) Manual displays a dialog for keystone correction. Use the cursor buttons ◄/► to select the direction to correct ( or ) then use the buttons ▲/▼ for adjustment. MAGNIFY ON HOME PAGE UP VOLUME OFF END PAGE DOWN MUTE FREEZE MY BUTTON KEYSTONE 1 2 POSITION MENU ESC ENTER RESET To close the dialog and complete this operation, press the KEYSTONE button again. Even if you don't do anything, the dialog will automatically disappear after a few seconds.   -';5610' ● The adjustable range of this function will vary among inputs. For some input, this function may not work well. ● When V:INVERT or H&V:INVERT is selected to the MIRROR item in the SETUP menu, if the projector screen is inclined or angled downward, this function may not work correctly. ● When the zoom adjustment is set to the TELE (telephoto focus), this function may be excessive. This function should be used when the zoom adjustment is set to the full WIDE (wide-angle focus) whenever possible. ● When the projector is placed on the level (about ±3°), this function may not work. ● When the projector is inclined to near ±30 degree or over, this function may not work well. ● This function will be unavailable when Transition Detector is on (50). 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

±9
Adjusting the position
±.
Press the POSITION button on the remote control.
The “POSITION” indication will appear on the screen.
².
Use the cursor buttons ▲/▼/◄/► to adjust the picture
position.
When you want to reset the operation, press the RESET button on the remote
control during the operation.
To complete this operation, press the POSITION button again. Even if you do
not do anything, the dialog will automatically disappear after a few seconds.
When this function is performed on a video signal, s-video signal or component video
signal, some image such as an extra-line may appear at outside of the picture.
When this function is performed on a video signal, s-video signal, or component video signal
of 5²5i (480i) or 6²5i (576i), the range of this adjustment depends on the OVER SCAN in
IMAGE menu
(
28
)
setting. It is not possible to adjust when the OVER SCAN is set to ±0.
Operating
Correcting the keystone distortions
±.
Press the KEYSTONE button on the
remote control. A dialog will appear on the
screen to aid you in correcting the distortion.
².
Use the cursor buttons
/
to select AUTO or
MANUAL operation, and press the button
to perform the following.
±)
AUTO executes automatic vertical keystone correction.
²)
Manual displays a dialog for keystone correction.
Use the cursor buttons ◄/► to select the direction to correct
(
or
) then use the buttons
▲/▼ for adjustment.
To close the dialog and complete this operation, press the
KEYSTONE button again. Even if you don’t do anything,
the dialog will automatically disappear after a few seconds.
● The adjustable range of this function will vary among inputs. For some input,
this function may not work well.
● When V:INVERT or H&V:INVERT is selected to the MIRROR item in the
SETUP menu, if the projector screen is inclined or angled downward, this
function may not work correctly.
● When the zoom adjustment is set to the TELE (telephoto focus), this function
may be excessive. This function should be used when the zoom adjustment is
set to the full WIDE (wide-angle focus) whenever possible.
When the projector is placed on the level (about ³3°), this function may not work.
When the projector is inclined to near ³30 degree or over, this function may not
work well.
This function will be unavailable when Transition Detector is on
(