Hitachi HTS722020K9SA00 Specifications - Page 51
Diagnostic and Reset considerations
UPC - 890552607150
View all Hitachi HTS722020K9SA00 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
7K200 SATA OEM Specification Register Error Sector Count LBA Low LBA Mid LBA High Device Status Alternate Status Table 30 Default Register Values Default Value Diagnostic Code 01h 01h 00h 00h 00h 50h 50h The meaning of the Error Register diagnostic codes resulting from power on, COMRESET or the Execute Device Diagnostic command are shown in the following table. Code 01h 02h 03h 04h 05h Table 31 Diagnostic Codes No error Detected Formatter device error Sector buffer error Ecc circuitry error Controller microprocessor error Description 12.2 Diagnostic and Reset considerations The Set Max password, the Set Max security mode and the Set Max unlock counter don't retain over a Power On Reset but persist over a COMRESET or Soft Reset. For each Reset and Execute Device Diagnostic, the Diagnostic is done as follows: Execute Device Diagnostic In all the above cases: Power on, COMRESET, Soft reset, and the EXECUTE DEVICE DIAGNOSTIC command the Error register is shown in the following table. Device 0 Passed Error Register Yes 01h No 0xh Where x indicates the appropriate Diagnostic Code for the Power on, COMRESET, Soft reset, or Device Diagnostic error. Table 32 Reset error register values 51/173