How To Use Power ON/OFF Button Plug unit in to a 120 volt AC electrical outlet. Press the POWER ON/OFF button to turn unit on. Press the POWER ON/OFF button again to turn unit off. ATTENTION: When the water in the tank is almost empty, the unit will shut off to indicate to the user to refill water. Mist Adjustment Setting Mist adjusts from Lowest output to Highest output . To increase the mist output, press the MIST INCREASE button. The corresponding Mist Level will be lit on the LCD display. To decrease mist output, press the MIST DECREASE button. Mist Temperature Setting When the humidifier is powered ON, it will be operating on the default setting, Cool Mist. COOL will be lit on the LCD display. To change the Mist Temperature from Cool Mist to Warm Mist, press the TEMP button. The mist temperature will change to Warm Mist, and WARM will be lit on the LCD display. To change the Mist Temperature back to Cool Mist, press the TEMP button again. The mist temperature will change to Cool Mist, and COOL will again be lit on the LCD display. NOTE: Once warm mist is selected, it will take 20 minutes to heat up before the mist becomes warm. Programmable Humidistat This unit has a Programmable Humidistat that can be set in 1% increments from 35%-60% humidity. To program the humidity level, press the HUMIDISTAT INCREASE + button. The humidity level will increase by 1% every time the button is pressed, and will show on the LCD display screen. Keep pressing the HUMIDISTAT INCREASE + button until the desired humidity level setting is reached. The LCD display will show the set humidity level for 5 seconds, then will default back to display the current humidity. To decrease the humidity level setting, press the HUMIDISTAT DECREASE button. The humidity level will decrease on the LCD display by 1%. Keep pressing the HUMIDISTAT DECREASE - button until the desired humidity level setting is reached. NOTE: To eliminate any programmed Humidistat setting, press either + or - until you reach "CO" level (One level above 60 and one level below 35). NOTE: When the set humidity level is reached, the humidifier will drop down to LOW MIST until the humidity in the room drops below the set humidity level, then will kick back up to the previous mist level setting before it dropped to low until the set humidity level is again reached. Night Light Press the NIGHT LIGHT button to turn on the night light. The light at the bottom of the water tank will turn on, illuminating the tank. Timer The timer will cycle through the following settings 1 hour, 2 hours, 4 hours, 8 hours, OFF. Press the TIMER button to activate the timer. The timer setting indicator on LCD display will read "1 Hr". To select the desired timer setting, keep pressing the TIMER button until the desired timer setting is lit on the timer setting indicator. To turn the timer OFF, press the TIMER button until no settings are lit on the timer setting indicator on the LCD Display. 6 How to Fill CAUTION: Before filling unit with water, turn the power off and unplug the unit from the outlet. NOTE: Always use two hands to carry the water tank. 1. Grasp tank handle and lift up from humidifier base. (Fig. 2) Warm Cool MIST HUMIDISTAT Fig. 2 Fig. 3 2. Turn the tank upside down-remove the tank cap by turning it counter-clockwise. (Fig. 3) 3. Fill the water tank with clean, cool (not cold) water. We recommend using distilled water if you live in a hard water area. (Fig. 4) Fig. 4 Fig. 5 4. Replace the tank cap by turning clockwise until tight. (Fig. 5) 5. Install the tank back on the base of the unit. Make sure the tank is firmly seated. (Fig. 6) Warm Cool NOTE: It is normal to have a small amount of water MIST HUMIDISTAT Fig. 6 in the base during and after use. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

6
7
How To Use
How to Fill
CAUTION:
Before filling unit with water, turn the power off and unplug the unit from the outlet.
NOTE:
Always use two hands to carry the water tank.
Power ON/OFF Button
Plug unit in to a 120 volt AC electrical outlet. Press the
POWER ON/OFF
button to turn unit on.
Press the
POWER ON/OFF
button again to turn unit off.
ATTENTION:
When the water in the tank
is almost empty, the unit will shut off to indicate to the user to refill water.
Mist Adjustment Setting
Mist adjusts from Lowest output
to Highest output
. To increase the mist output, press the
MIST INCREASE
button. The corresponding Mist Level will be lit on the LCD display. To decrease
mist output, press the
MIST DECREASE
button.
Mist Temperature Setting
When the humidifier is powered ON, it will be operating on the default setting, Cool Mist.
COOL
will
be lit on the LCD display. To change the Mist Temperature from Cool Mist to Warm Mist, press the
TEMP
button. The mist temperature will change to Warm Mist, and
WARM
will be lit on the LCD
display. To change the Mist Temperature back to Cool Mist, press the
TEMP
button again. The mist
temperature will change to Cool Mist, and
COOL
will again be lit on the LCD display.
NOTE:
Once
warm mist is selected, it will take 20 minutes to heat up before the mist becomes warm.
Programmable Humidistat
This unit has a Programmable Humidistat that can be set in 1% increments from 35%-60% humidity.
To program the humidity level, press the
HUMIDISTAT INCREASE +
button. The humidity level
will increase by 1% every time the button is pressed, and will show on the LCD display screen. Keep
pressing the
HUMIDISTAT INCREASE +
button until the desired humidity level setting is reached.
The LCD display will show the set humidity level for 5 seconds, then will default back to display the
current humidity. To decrease the humidity level setting, press the
HUMIDISTAT DECREASE -
button. The humidity level will decrease on the LCD display by 1%. Keep pressing the
HUMIDISTAT
DECREASE -
button until the desired humidity level setting is reached.
NOTE:
To eliminate any programmed Humidistat setting, press either
+
or
-
until you reach "CO" level
(One level above 60 and one level below 35).
NOTE:
When the set humidity level is reached, the humidifier will drop down to
LOW MIST
until the
humidity in the room drops below the set humidity level, then will kick back up to the previous mist
level setting before it dropped to low until the set humidity level is again reached.
Night Light
Press the
NIGHT LIGHT
button to turn on the night light. The light at the bottom of the water tank
will turn on, illuminating the tank.
Timer
The timer will cycle through the following settings 1 hour, 2 hours, 4 hours, 8 hours, OFF. Press the
TIMER
button to activate the timer. The timer setting indicator on LCD display will read “
1 Hr
”. To
select the desired timer setting, keep pressing the
TIMER
button until the desired timer setting is lit
on the timer setting indicator. To turn the timer OFF, press the
TIMER
button until no settings are lit on
the timer setting indicator on the LCD Display.
1. Grasp tank handle and lift up from humidifier base. (Fig. 2)
2. Turn the tank upside down—remove the tank cap by turning it
counter-clockwise. (Fig. 3)
3. Fill the water tank with clean, cool (not cold) water. We
recommend using distilled water if you live in a hard water area.
(Fig. 4)
4. Replace the tank cap by turning clockwise until tight. (Fig. 5)
5. Install the tank back on the base of the unit. Make sure the tank is
firmly seated. (Fig. 6)
NOTE:
It is normal to have a small amount of water
in the base during and after use.
Fig. 2