HoMedics WFL-ISL User Manual - Page 4

Troubleshooting, Maintenance

Page 4 highlights

Figure 7 Drip Loop Maintenance • To clean the pump: Unplug from electrical outlet. Remove it from the base of the fountain. Use a small brush or stream of water to remove any debris. (Fig 8) • To keep water clean: Periodically change water and clean the product according to the water condition. Keeping the water clean prevents the water from becoming sticky and forming micro-organisms. We recommend distilled water to prevent mineral build-up. • To clean off hard water deposits on the base: Soak the container in a mixture of vinegar and water to clean and remove any mineral build-up. • Keeping the water at an optimum level: Add water periodically to keep water level at an optimum level to avoid shortening the life of the pump. NOTE: Never let the pump run dry, as this will shorten the life of the pump. • Fountain Storage Unplug the fountain from the electrical outlet, empty the water, and store fountain in a dry, cool place. 6 Figure 8 PVC Tubing Inserts Here Back Plate Pump Inlet Front Plate Impeller Flow Control Lever Housing Suction Feet Caution: All servicing of this fountain must be performed by authorized HoMedics service personnel only. Troubleshooting • If the pump fails to operate, check the following: Check the circuit breaker, or try a different outlet to make sure the pump is getting electrical power. NOTE: Always disconnect from electrical outlet before handling the pump. • If the pump gurgles, spews, or "burps": Check the water level to make sure the pump has enough water to function. •Obtaining a desired water level: Check the water level daily the first week to measure the rate of evaporation; refill with water as needed. •If water is splashing outside the fountain: Adjust the flow control lever to a lower setting on the pump. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

7
6
Troubleshooting
• If the pump fails to operate, check the following:
Check the circuit breaker, or try a different outlet to make
sure the pump is getting electrical power.
NOTE: Always disconnect from electrical outlet
before handling the pump.
• If the pump gurgles, spews, or “burps”:
Check the water level to make sure the pump has enough
water to function.
•Obtaining a desired water level:
Check the water level daily the first week to measure the rate
of evaporation; refill with water as needed.
•If water is splashing outside the fountain:
Adjust the flow control lever to a lower setting on the pump.
Caution:
All servicing
of this fountain
must be
performed
by authorized
HoMedics
service
personnel only.
Drip Loop
Figure 7
Maintenance
• To clean the pump:
Unplug from electrical outlet. Remove it from the base of the fountain.
Use a small brush or stream of water to remove any debris. (Fig 8)
• To keep water clean:
Periodically change water and clean the product according to the water
condition. Keeping the water clean prevents the water from becoming
sticky and forming micro-organisms. We recommend distilled water to
prevent mineral build-up.
• To clean off hard water deposits on the base:
Soak the container in a mixture of vinegar and water to clean and
remove any mineral build-up.
• Keeping the water at an optimum level:
Add water periodically to keep water level at an optimum level to avoid
shortening the life of the pump.
NOTE: Never let the pump run dry, as this will shorten
the life of the pump.
• Fountain Storage
Unplug the fountain from the electrical outlet, empty the water, and store
fountain in a dry, cool place.
Figure 8
Front Plate
PVC Tubing
Inserts Here
Back Plate
Suction Feet
Impeller
Pump Inlet
Flow
Control
Lever
Housing