Honeywell 748LC Product Guide - Page 13

Glassbreak Detectors

Page 13 highlights

Glassbreak Detectors FG-1625 Glassbreak Detector "Great new styling with field-proven performance." Features • FlexCore™ processing • New hinged-case styling - nearly 180° opening • Adjustable sensitivity • No minimum range • Remote Test Mode Enable • Protected PCB • Only sensor UL listed for coated and double-pane glass • Available with tamper/Form C as FG-1625T • Available as non-adjustable with 15ft range as FG-1615 Specifications: • Range: 25' maximum; no minimum • Glass types: plate, tempered, laminated, wired, coated, double-pane • Sensitivity: four levels set via DIP switch • Alarm relay: Form A • Input voltage: 6-18VDC • Standby current: 12mA typical at 12V • Indicators: Red (alarm) and green (test) LEDs • Operating temp: 14°F to 122°F • Dimensions: 4.5"H x 2.8"W x 1.0"D • Tester: FG-701 FG-1625F Flush Mount Glassbreak Detector "Great new flush mount styling that generously covers all gang box designs." Features • FlexCore™ processing • New case styling covers all types of single gang boxes • Adjustable sensitivity • No minimum range • Remote Test Mode Enable • Protected PCB with tamper switch • Only sensor UL listed for coated and double-pane glass • Available for double-gang electrical box as FG-1525FD 12 Specifications: • Range: 25' maximum; no minimum • Glass types: All types - same as FG-1625 • Sensitivity: four levels set via DIP switch • Alarm relay: Form A • Input voltage: 6-18VDC • Standby current: 12mA typical at 12V • Indicators: Red (alarm) and green (test) LEDs • Operating temp: 14°F to 122°F • Dimensions: • FG-1625F: Faceplate - 4.9"H x 3.3"W • FG-1525FD: Faceplate - 4.49" x 4.49" • Tester: FG-701

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Glassbreak Detectors
FG-1625
Glassbreak Detector
“Great new styling with
field-proven performance.”
Features
• FlexCore™ processing
• New hinged-case styling – nearly
180° opening
• Adjustable sensitivity
• No minimum range
• Remote Test Mode Enable
• Protected PCB
• Only sensor UL listed for coated
and double-pane glass
• Available with tamper/Form C
as FG-1625T
• Available as non-adjustable
with
15ft range as FG-1615
Specifications:
• Range: 25’ maximum; no minimum
• Glass types: plate, tempered,
laminated, wired, coated, double-pane
• Sensitivity: four levels set via DIP switch
• Alarm relay: Form A
• Input voltage: 6-18VDC
• Standby current: 12mA typical at 12V
• Indicators: Red (alarm) and
green (test) LEDs
• Operating temp: 14°F to 122°F
• Dimensions: 4.5”H x 2.8”W x 1.0”D
• Tester: FG-701
FG-1625F
Flush Mount
Glassbreak Detector
“Great new flush mount
styling that generously
covers all gang box
designs.”
Features
• FlexCore™ processing
• New case styling covers all types of
single gang boxes
• Adjustable sensitivity
• No minimum range
• Remote Test Mode Enable
• Protected PCB with tamper switch
• Only sensor UL listed for coated and
double-pane glass
• Available for double-gang electrical box
as FG-1525FD
Specifications:
• Range: 25’ maximum; no minimum
• Glass types: All types – same
as FG-1625
• Sensitivity: four levels set via DIP switch
• Alarm relay: Form A
• Input voltage: 6-18VDC
• Standby current: 12mA typical at 12V
• Indicators: Red (alarm) and
green (test) LEDs
• Operating temp: 14°F to 122°F
• Dimensions:
• FG-1625F: Faceplate – 4.9”H x 3.3”W
• FG-1525FD: Faceplate – 4.49” x 4.49”
• Tester: FG-701
12