Honeywell 748LC Product Guide - Page 15

FG-1025Z, Glassbreak Detector with, Exclusion Zone, FG-1625SN, V-Plex Glassbreak Detector

Page 15 highlights

Glassbreak Detectors FG-1025Z Glassbreak Detector with Exclusion Zone "Exclusive dual microphone design provides unbeatable false alarm immunity." Features • Patented Time-of-Arrival processing with dual microphones improves false alarm immunity in its "Exclusion Zone" • Remote Test Mode Enable • Only sensor UL listed for coated and double-pane glass Specifications: • Range: 25' maximum; no minimum • Glass types: plate, tempered, laminated, wired, coated, double-pane • Alarm relay: Form C • Input voltage: 6-18VDC • Standby current: 12mA typical at 12V • Indicators: Red (alarm) and green (test) LEDs • Operating temp: 14°F to 122°F • Dimensions: 4.25"Diameter x 0.9"D • Tester: FG-701 FG-1625SN V-Plex Glassbreak Detector "Looks, sets up and performs like the hardwired version...ultimate glassbreak performance for V-Plex polling loop." Features • Serial number addressable • New hinged-case styling same as FG-1625 • Set-up and performance identical to FG-1625 14 Specifications: • Range: 25' maximum • Glass types: plate, tempered, laminated, wired, coated, double-pane • Sensitivity: four levels set via DIP switch • Alarm relay: VPlex polling loop • Input voltage: 7-11VDC for polling loop • Standby current:

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Glassbreak Detectors
14
FG-1025Z
Glassbreak Detector with
Exclusion Zone
“Exclusive dual microphone
design provides unbeatable
false alarm immunity.”
Features
• Patented Time-of-Arrival processing with
dual microphones improves false alarm
immunity in its “Exclusion
Zone”
• Remote Test Mode Enable
• Only sensor UL listed for coated and
double-pane glass
Specifications:
• Range: 25’ maximum; no minimum
• Glass types: plate, tempered,
laminated, wired, coated, double-pane
• Alarm relay: Form C
• Input voltage: 6-18VDC
• Standby current: 12mA typical at 12V
• Indicators: Red (alarm) and green (test)
LEDs
• Operating temp: 14°F to 122°F
• Dimensions: 4.25”Diameter x 0.9”D
• Tester: FG-701
FG-1625SN
V-Plex Glassbreak Detector
“Looks, sets up and
performs like the hardwired
version…ultimate glassbreak
performance for
V-Plex polling loop.”
Features
• Serial number addressable
• New hinged-case styling same
as FG-1625
• Set-up and performance identical
to FG-1625
Specifications:
• Range: 25’ maximum
• Glass types: plate, tempered,
laminated, wired, coated, double-pane
• Sensitivity: four levels set via
DIP switch
• Alarm relay: VPlex polling loop
• Input voltage: 7-11VDC for polling loop
• Standby current: <2mA
• Indicators: Red (alarm) and green (test)
LEDs
• Operating temp: 14°F to 122°F
• Dimensions: 4.5”H x 2.8”W x 1.0”D
• Tester: FG-701