Honeywell 748LC Product Guide - Page 15
FG-1025Z, Glassbreak Detector with, Exclusion Zone, FG-1625SN, V-Plex Glassbreak Detector
View all Honeywell 748LC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Glassbreak Detectors FG-1025Z Glassbreak Detector with Exclusion Zone "Exclusive dual microphone design provides unbeatable false alarm immunity." Features • Patented Time-of-Arrival processing with dual microphones improves false alarm immunity in its "Exclusion Zone" • Remote Test Mode Enable • Only sensor UL listed for coated and double-pane glass Specifications: • Range: 25' maximum; no minimum • Glass types: plate, tempered, laminated, wired, coated, double-pane • Alarm relay: Form C • Input voltage: 6-18VDC • Standby current: 12mA typical at 12V • Indicators: Red (alarm) and green (test) LEDs • Operating temp: 14°F to 122°F • Dimensions: 4.25"Diameter x 0.9"D • Tester: FG-701 FG-1625SN V-Plex Glassbreak Detector "Looks, sets up and performs like the hardwired version...ultimate glassbreak performance for V-Plex polling loop." Features • Serial number addressable • New hinged-case styling same as FG-1625 • Set-up and performance identical to FG-1625 14 Specifications: • Range: 25' maximum • Glass types: plate, tempered, laminated, wired, coated, double-pane • Sensitivity: four levels set via DIP switch • Alarm relay: VPlex polling loop • Input voltage: 7-11VDC for polling loop • Standby current: