6 Set Thermostat ❑ Move the temperature setting lever to the required temperature comfort level. CT40A HEATING THERMOSTAT 7 Troubleshoot Thermostat Your Honeywell thermostat requires minimal attention. Most problems can be corrected as described in Table 2. Symptom No heat. Furnace turns on and off. Major swings in temperature of greater than 1°C (2°F) when outside temperature is stable. Thermostat setting and thermometer reading disagree. Table 2. Troubleshooting. Problem Blown fuse or tripped circuit breaker. Furnace power switch is set to Off. No pilot flame. Incorrect connections to thermostat. Other. Burner on period is too short. Burner on period is too long. Thermostat affected by drafts or radiant heat. Corrective Action Replace fuse or reset circuit breaker. Turn furnace power switch to On. For standing pilot applications, relight pilot flame per furnace manufacturer's instructions. With power to furnace set to Off: • Tighten all mounting and terminal screws. • Repair frayed or broken wires. Contact a qualified service technician for assistance. Remove the thermostat cover and move the heat anticipator lever counterclockwise one scale mark. Replace the cover and wait several hours for the system to stabilize. Remove the thermostat cover and move the heat anticipator lever clockwise one scale mark. Replace the cover and wait several hours for the system to stabilize. Contact qualified service technician to change the location. The thermostat should be about 1.5 m (5 ft) above the floor and on an inside wall. 3 69-0847B-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

CT40A HEATING THERMOSTAT
3
69-0847B-1
6 Set Thermostat
Move the temperature setting lever to the required
temperature comfort level.
7 Troubleshoot Thermostat
Your Honeywell thermostat requires minimal attention.
Most problems can be corrected as described in Table 2.
Table 2. Troubleshooting.
Symptom
Problem
Corrective Action
No heat.
Blown fuse or tripped circuit breaker.
Replace fuse or reset circuit breaker.
Furnace power switch is set to Off.
Turn furnace power switch to On.
No pilot flame.
For standing pilot applications, relight pilot
flame per furnace manufacturer’s
instructions.
Incorrect connections to thermostat.
With power to furnace set to Off:
°
Tighten all mounting and terminal
screws.
°
Repair frayed or broken wires.
Other.
Contact a qualified service technician for
assistance.
Furnace turns on and off.
Burner on period is too short.
Remove the thermostat cover and move
the heat anticipator lever counter-
clockwise one scale mark. Replace the
cover and wait several hours for the
system to stabilize.
Major swings in temperature
of greater than 1²C (2²F)
when outside temperature is
stable.
Burner on period is too long.
Remove the thermostat cover and move
the heat anticipator lever clockwise one
scale mark. Replace the cover and wait
several hours for the system to stabilize.
Thermostat setting and
thermometer reading
disagree.
Thermostat affected by drafts or
radiant heat.
Contact qualified service technician to
change the location. The thermostat
should be about 1.5 m (5 ft) above the
floor and on an inside wall.