Honeywell DG115EZIAQ Owners Guide - Page 21
Setup, functions, Settings, Options
UPC - 085267313025
View all Honeywell DG115EZIAQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Advanced programming Setup functions Settings & Options (factory default in bold) 85 Hum Service Timer 0,1,3,6,12 (months intermittent) 90 Hum Water Filter Service 0,1,3,6,12 (months intermittent) 95 Air Filter Service Timer 0,1,3,6,12 (months continuous) 100 Vent Filter Service Timer 0,1,3,6,12 (months continuous) 105 Vent Service Type 0=Clean ventilation filter 1=Change ventilation filter 110 UV Bulb Service Reminder 0,6,12,24 (months continuous) 115 Vent Options 0=No vent installed 1=Ventilation using VENT contacts 2=Ventilation using VENT contacts for high speed and DEHUM contacts for low speed (only if dehum not installed) 3=Ventilation using VENT contacts and DEHUM contacts activated together (auxiliary ventilation device such as exhaust fan) 120 Vent Operation 0=Vent forces HVAC fan on 1=Vent operates independent of HVAC fan 125 Programmed Vent 0=OFF; 1=ON 130 Program Start Time 15 min increments (appears only if ISU125=1) 5:00 PM 135 Program End Time 15 min increments (appears only if ISU125=1) 9:00 AM 140 ASHRAE: # of Bedrooms 1-6 bedrooms; 2 145 ASHRAE: Home's Sq Ft 10=1,000 Sq Ft; up to 50=5,000 Sq Ft 19 69-2072-05 69-2072_C.indd 19 7131/2008 2:04:28 PM