Honeywell F500A1000 Owner's Manual - Page 4
Installation - hepa air cleaner
View all Honeywell F500A1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
F500 WHOLE HOUSE/ LIGHT COMMERCIAL HEPA FILTRATION SYSTEM S688A1007 SAIL SWITCH (OPTIONAL) 120 VAC 60 HZ SUPPLY WITH GROUND FRESH AIR HEAT RECOVERY VENTILATOR RETURN AIR F500 HIGH EFFICIENCY AIR CLEANER AIR HANDLER (FURNACE) M20264A Fig. 4. Typical F500 bypass installation with heat recovery ventilator. INSTALLATION When Installing this Product... 1. Read these instructions carefully. Failure to follow these instructions could damage the product or cause a hazardous condition. 2. Check the ratings on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. Unpacking Whole House/Light Commercial HEPA Filtration System The Whole House/Light Commercial HEPA Filtration System is shipped fully assembled. Check that all the components are included. The carton contains the following: • F500A or F500B Whole House/Light Commercial HEPA Filtration System. • Activated carbon-odor filter, pleated prefilter, HEPA filter. • HEPA AIRWATCH™ Indicator. • Four isolation mounting straps. • Literature. Mounting and Ducting 1. Mount four vibration isolation straps to the side of the HEPA System using the mounting screws located on the cabinet. 2. Securely fasten the other ends of the straps to the floor joists with wide-head nails or screws (not supplied); be sure the unit is level. 3. Connect the HEPA System to the return air duct. See Fig. 1 and 2. Seal all duct joints with caulk, mastic, or high quality foil duct tape. Installing Whole House/Light Commercial HEPA Filtration System Electrical Connections The F500 has a 3-prong, 120 Vac connector plug with ground. If further wiring is required, contact a qualified electrician to make all electrical connections. IMPORTANT Be sure the unit is grounded correctly. The F500 can be installed either to run continuously or to run only when the HVAC system blower is operating. • To run the air cleaner continuously, simply plug the air cleaner into a 120 Vac outlet. The unit turns on and operates continuously when the power switch is turned on. • To run the air cleaner only when the system blower is on, use an optional Honeywell S688A1007 Sail Switch in the return air duct. See the S688A product literature for correct installation procedures. WHITE BROWN BROWN ON/OFF SWITCH DOOR INTERLOCK FAN MOTOR CAPACITOR BLACK BLUE TERMINAL BLOCK BLACK GREEN WHITE POWER CORD M20265 Fig. 5. F500 internal wiring diagram. 68-0263-2 4