Replacing electronic air cleaner components STEP 1 Inspect the cells for broken ionizer wires and bent collector plates. Repair as necessary or take to a Honeywell Authorized Air Cleaner Repair Station. STEP 2 Slide the prefilters into the upstream prefilter guides. STEP 3 Slide the air cleaner cells in so the air flow arrow points downstream and the handles face outward. STEP 4 Firmly close the access door. STEP 5 Turn on the air cleaner. If the cells and prefilters are wet, the neon light may not come on and you may hear arcing. If the arcing is annoying, simply turn the air cleaner off for 2-3 hours or until the cells are dry. If your air cleaner has an Air Cleaner Monitor, the FAULT indicator may activate if you install wet cells and prefilters. Again, if the neon light or the FAULT indicator annoys you, simply turn off the air cleaner for 2-3 hours or until the cells and prefilters are dry. M3582 69-0764-2 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

69-0764—2
Replacing electronic
air cleaner components
STEP 1
Inspect the cells for broken ionizer wires and
bent collector plates. Repair as necessary or
take to a Honeywell Authorized Air Cleaner
Repair Station.
STEP 2
Slide the prefilters into the upstream prefilter
guides.
STEP 3
Slide the air cleaner cells in so the air flow
arrow points downstream and the handles face
outward.
STEP 4
Firmly close the access door.
STEP 5
Turn on the air cleaner. If the cells and prefilters
are wet, the neon light may not come on and
you may hear arcing. If the arcing is annoying,
simply turn the air cleaner off for 2-3 hours or
until the cells are dry.
If your air cleaner has an Air Cleaner Monitor,
the FAULT indicator may activate if you install
wet cells and prefilters. Again, if the neon light
or the FAULT indicator annoys you, simply turn
off the air cleaner for 2-3 hours or until the cells
and prefilters are dry.