Honeywell IS215T Installation Instructions

Honeywell IS215T Manual

Honeywell IS215T manual content summary:

  • Honeywell IS215T | Installation Instructions - Page 1
    Motion Sensor Installation Instructions ❶ Select the mounting location. ❷ Separate the sensor housings and remove the printed circuit board (PCB). • Use a small screwdriver to push in the housing latch at the bottom of the sensor, and gently pull apart the housings. ❸ Mount the unit. Wiring
  • Honeywell IS215T | Installation Instructions - Page 2
    215T Passive Infrared Motion Sensor Product Information ALARM LED DISABLE After walk-testing the sensor Security Grade 2 Environmental Class II Important: For UL Certificated installations, the IS215T Honeywell International Inc. • Honeywell and IntelliSense are registered trademarks of Honeywell
  • 1
  • 2

Select the mounting location.
Wire the unit.
Mount the unit.
Mounting Location Guidelines
°
2.3 m (7±6²) mounting height
°
Avoid direct or reflected sunlight
°
Aim sensor away from windows or heating/
cooling devices
°
Sensor must have a clear line-of-sight to
protected area
°
Push outward on the
PCB latch and lift the
PCB out of the hous-
ing.
°
Slide the wire through the wire channel and wire
access in the back housing.
°
Mount the back housing flat against a wall or in a
corner.
°
Replace the PCB.
°
Connect wires as shown using 0.64 - 1.63 mm
2
(14 to 22 AWG) wire size.
Observe proper
polarity.
Corner
Mount
Wire Channel
Wall Mount
IS-215T Passive Infrared Motion Sensor Installation Instructions
Separate the sensor housings and re-
move the printed circuit board (PCB).
Corner
Mount
Wiring Knockouts
POWER
12VDC
10mA
ALARM
16VDC
90mA
TAMPER
30VDC
0.5A
Configure the sensor sensitivity.
°
Configure the IS-215T for the sensitivity best
suited to the application.
ON
OFF
SENSITIVITY
SWITCH SW2 POSITION
High (pulse count 1)
Low [Normal] (pulse count 2)
Walk-test the sensor.
High Sensitivity:
2-4 Steps
(Pulse Count 1)
Switch
°
Use a small screwdriver to
push in the housing latch
at the bottom of the sensor,
and gently pull apart the
housings.
Alarm
LED
Low [Normal] Sensitivity:
3-5 Steps
(Pulse Count 2)