IS-215T Passive Infrared Motion Sensor Product Information - pir

Page 2 highlights

IS-215T Passive Infrared Motion Sensor Product Information ALARM LED DISABLE After walk-testing the sensor, disable the alarm LED by turning Switch S1 to the OFF position. DETECTION PATTERNS TOP VIEW Wide Angle Lens SPECIFICATIONS Range: 12 m x 12 m 40' x 40' Power requirements: 10 - 14 VDC, w/LED - Alarm: 10mA max.; w/o LED - Alarm: 7mA max.; 12 VDC 3V peak-to-peak at nominal 12 VDC Alarm relay: Form A SPST, 90 mA, 16 VDC, 15 Ohm protective resistor Tamper switch Closed with cover in place 0.5 A, 30 VDC RFI immunity: 30 V/m 10 MHz - 1000 MHz PIR White light immunity: 6,500 Lux PIR sensitivity: Switch selectable low [normal] (pulse count 2) 3-5 steps high (pulse count 1) 2-4 steps PIR fields of view: dual element, 44 long range zones 14 intermediate, 8 lower, 4 look-down Operating temperature: -10o C to +55o C (14° F to 131° F) Relative humidity: 5% to 95% noncondensing Dimensions: 8.57 cm x 6.03 cm x 3.81 cm (3-3/8" H x 2-3/8" W x 1-1/2" D) Weight: 66.62 g (2.35 oz) Packaged Product is 92.14 g (3.25 oz) Approvals/listings: CE cULus C-Tick EN 50131-1 Security Grade 2 Environmental Class II Important: For UL Certificated installations, the IS215T must be connected to a UL listed power supply or UL listed control unit capable of providing a minimum of four hours of standby power. Suitable for connection to an EN 60950 Class II Limited Power Source. SIDE VIEW Wide Angle Lens © 2004 Honeywell International Inc. • Honeywell and IntelliSense are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. 5-051-680-40 Rev C

  • 1
  • 2

' 2004 Honeywell International Inc.
° Honeywell and IntelliSense are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved.
IS-215T Passive Infrared Motion Sensor Product Information
ALARM LED DISABLE
After walk-testing the sensor, disable the alarm
LED by turning Switch S1 to the OFF position.
SPECIFICATIONS
Range:
12 m x 12 m
40’ x 40’
Power requirements:
10 - 14 VDC, w/LED - Alarm:
10mA max.; w/o LED - Alarm:
7mA max.; 12 VDC
3V peak-to-peak at nominal
12 VDC
Alarm relay:
Form A SPST,
90 mA, 16 VDC,
15 Ohm protective resistor
Tamper switch
Closed with cover in place
0.5 A, 30 VDC
RFI immunity:
30 V/m
10 MHz - 1000 MHz
PIR White light immunity:
6,500 Lux
PIR sensitivity:
Switch selectable
low [normal] (pulse count 2)
3-5 steps
high (pulse count 1) 2-4 steps
PIR fields of view:
dual element,
44 long range zones
14 intermediate, 8 lower,
4 look-down
Operating temperature:
-10
o
C to +55
o
C (14³ F to 131³ F)
Relative humidity:
5% to 95% noncondensing
Dimensions:
8.57 cm x 6.03 cm x 3.81 cm
(3-3/8" H
x 2-3/8" W
x 1-1/2" D)
Weight:
66.62 g
(2.35 oz)
Packaged Product is 92.14 g
(3.25 oz)
Approvals/listings:
CE
cULus
C-Tick
EN 50131-1
Security Grade 2
Environmental Class II
Important:
For UL Certificated installations, the IS215T must
be connected to a UL listed power supply or UL listed control
unit capable of providing
a minimum of four hours
of standby
power.
Suitable for connection to an EN 60950 Class II Limited Power
Source.
TOP VIEW
Wide Angle Lens
DETECTION PATTERNS
SIDE VIEW
Wide Angle Lens
5-051-680-40
Rev C