Honeywell T8090A Owner's Manual - Page 14

Troubleshooting - instruction

Page 14 highlights

Troubleshooting Your Honeywell thermostat requires little or no attention. Most problems can generally be traced to the following: Problem No heat. 69-0574-2 Check Action - system switch. May be in OFF or Move system switch to HEAT position. COOL position. 1 - fuse or circuit breaker. If blown or tripped, replace fuse or reset breaker. - furnace power switch. May be Off. Move switch to ON. - pilot flame. May be out. Relight pilot flame per furnace manufacturers instructions. - R and W thermostat connections. Turn Off power to furnace. Check for correct terminal hookups. Repair any frayed or broken wires. Firmly tighten all terminal screws. Turn On power. - other problem. Contact a qualified service technician for assistance. (continued) 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

69-0574—2
14
Troubleshooting
Your Honeywell thermostat requires little or no attention. Most problems can generally be
traced to the following:
Problem
Check
Action
No heat.
system switch. May be in OFF or
COOL position.
Move system switch to HEAT position.
fuse or circuit breaker.
If blown or tripped, replace fuse or reset
breaker.
furnace power switch. May be Off.
Move switch to ON.
pilot flame. May be out.
Relight pilot flame per furnace manufacturers
instructions.
R and W thermostat connections.
Turn Off power to furnace. Check for correct
terminal hookups. Repair any frayed or
broken wires. Firmly tighten all terminal
screws. Turn On power.
other problem.
Contact a qualified service technician for
assistance.