Honeywell TE852W User Manual - Page 21
Specifications
UPC - 843616002521
View all Honeywell TE852W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Milan, Italy MIL 1 SE Singapore, SIN 8 NO Montevideo, MVD -3 SM Sofia, Bulgaria SOF 2 SE Moscow, Russia MOW 3 SK Stockholm Arlanda, ARN 1 SE Munich, Germany MUC 1 SE Sydney, Australia SYD 10 SA Nairobi, Kenya NBO 3 NO Tokyo, Japan TKO 9 NO Nanjing NKG 8 NO Tripoli, Libya TRP 2 NO Naples, Italy NAP 1 SE Vienna, Austria VIE 1 SE New Delhi, India DEL 5.5 NO Warsaw, Poland WAW 1 SE Odessa, Ukraine ODS 2 SE Zürich, Switzerland ZRH 1 SE Osaka, Japan KIX 9 NO DST (Daylight Savings Time) definitions: SA = Australian DST. SB = South Brazilian DST. Changes annually. SC = Chile DST SE = Standard European DST. SG = Egypt DST SH = Havana, Cuba DST SI = Iraq and Syria DST SK = Irkutsk & Moscow DST SM = Montevideo, Uruguay DST SN = Namibia DST SP = Paraguay DST SQ = Iran DST maybe changed annually. ST = Tasmania DST SU = Standard American DST. SZ = New Zealand DST NO DST = no = Places that do not observe DST; ON = Always add 1 hour to the local standard time SPECIFICATIONS Radio Frequency: 433 MHz RF Reception range: 100-328 feet (30 -100 m) Barometric Pressure Measuring Range: 14.75 inHg to 32.44 inHg (500 Hpa to 1100Hpa); (374.5 mmHg to 823.8 mmHg) Resolution: 0.003 inHg (0.1 Hpa, 0.08 mmHg) Accuracy: 0.015 inHg (5 Hpa; 0.38 mmHg) Sampling interval: 20 minutes Altitude Compensation Range: -657 ft to 16404 ft (-200m to +5000 m) Temperature (Indoor) 41 Operating Range: 23°F to 122°F (-5°C to 50°C) Resolution: 0.2°F (0.1°C) Accuracy: 2°F (1°C) Sampling Interval: 10 seconds Temperature (remote) Range: -40°F to 176°F (-40°C to 80°C) Resolution: 0.2°F (0.1°C) Accuracy: 2°F (1°C) Transmitting Interval: around 47 seconds Humidity (Indoor) Operating Range: 30% to 80% Resolution: 1% Accuracy: 5% Sampling Interval: 10 seconds Humidity (Outdoor) Operating Range: 30% to 80% Resolution: 1% Accuracy: 5% Sampling Interval: 10 seconds Transmitting Interval: around 47 seconds Sunrise and Sunset Accuracy: 1min (latitude within 50°) Wind Speed Range: 0 to 199.9mph (199.9 Km/h, 173.7 Knots, 89.3 m/s) Resolution: 0.1mph (0.16 Km/h) Accuracy: (2mph + 5%) Starting Threshold: 3mph (4.8 Km/h) Wind/Gust Speed Display Update Interval: 33 seconds Wind/Gust Sampling Interval: 11 seconds Power Main unit: 2 x UM-3 or AA 1.5V battery Remote Thermo Hygrometer: 2 x UM-3 or AA 1.5V battery Remote Wind Meter: 2 x UM-3 or AA 1.5V battery Battery life (alkaline) Main unit: 2 month Thermo-Hygrometer: over 12 months Remote Wind Meter: over 12 months Weight (without batteries) Main unit: 8.15oz (231g) Remote Thermo-Hygrometer: 2.29oz (65g) Remote Wind Meter: 11.12oz (315g) Dimensions 41 42