Troubleshooting Guide - n cartridge
UPC - 328785251005
View all Honeywell V5100N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Troubleshooting Guide If your Humidifier is not working properly, refer to the following: Problem Power Switch is set to "On" and Power Lamp is off Possible Cause • Unit not plugged in • No power at outlet Solution • Plug unit in • Check circuits, fuses, try a different outlet. Little or no mist is produced • No water in tank • Unit is not level • Mineral deposits on Nebulizer or Water Sensor • Water Tank was washed with detergent • Blower not operating • Demineralization Cartridge is clogged • Nebulizer not functioning • Fill Water Tank. • Place on a level surface. • Clean Nebulizer and Water Sensor per instructions. • Rinse thoroughly with clean water. Wipe Dry. • Ensure water in Base is adequate to immerse Water Sensor. • Remove Cartridge and restart machine. If mist resumes, replace with a new Cartridge (#DC-51). • See Warranty Condensation forms around humidifier or windows • Mist Intensity is set too high for room size or preexisting humidity level. • Decrease mist output using the Mist Intensity Control. White Dust Accumulation • Hard water used • Demineralization Cartridge needs replacement • Use distilled water or a Demineralization Cartridge. • Replace Demineralization Cartridge (Model DC-51) Note: Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit. Customer failure to follow these instructions may void the warranty.