Hoover U5265-900 Manual - Page 10

Lubrication

Page 10 highlights

3-21 3-22 3-23 C D With lettering to the outside of belt, slide new belt along side of cleaner cavity and over motor pulley (C). Insert agitator through belt and place belt in belt guide (D). 3-24 3-25 E F Grasp agitator firmly and fit it into position by first sliding end opposite the belt into the rectangular slot (E) on side of cleaner. Pull other side of agitator (F) into place. Turn agitator, making sure belt is not pinched between agitator and cleaner body. The belt must rotate freely inside the belt guide. If the agitator does not turn, reposition belt in the belt guide. 3-26 B Replace agitator cover (B) and 2 screws. Replace hood, 2 screws and hose. Raise nozzle up and replace the 2 screws on the bottom. The agitator brush roll When to replace When agitator brushes are worn, the agitator should be replaced. To check condition of brushes, disconnect cleaner from electrical outlet. Move edge of a card across bottom plate while turning agitator. To maintain cleaning effectiveness, replace agitator if brushes do not touch card. What to buy When purchasing a new agitator, ask for HOOVER part no. 48414130. 3-27 How to replace Disconnect cleaner from electrical outlet. Remove hood and agitator cover as described in the "Belt replacement" section. Discard old agitator. Continue following the directions in the "Belt replacement" section to replace belt, new agitator, agitator cover and hood. Lubrication The motor is equipped with bearings that contain sufficient lubrication for the life of the motor. The addition of lubricant could cause damage. Therefore, do not add lubricant to motor bearings. The agitator brush roll is equipped with two ball bearings that should be lubricated periodically by a Hoover Factory Service Center or an Authorized Hoover Warranty Service Dealer (Depot). 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Lubrication
The motor is equipped with bearings
that contain sufficient lubrication for the
life of the motor. The addition of lubricant
could cause damage.
Therefore, do
not add lubricant to motor bearings.
The agitator brush roll is equipped with
two ball bearings that should be lubri-
cated periodically by a Hoover Factory
Service Center or an Authorized Hoover
Warranty Service Dealer (Depot).
The agitator brush roll
When to replace
When agitator brushes are worn, the
agitator should be replaced.
To check condition of brushes,
discon-
nect cleaner from electrical outlet.
Move edge of a card across bottom
plate while turning agitator. To maintain
cleaning effectiveness, replace agitator
if brushes do not touch card.
What to buy
When purchasing a new agitator, ask for
HOOVER part no. 48414130.
10
3-24
How to replace
Disconnect cleaner from electrical
outlet.
Remove hood and agitator cover as
described in the “Belt replacement”
section.
Discard old agitator.
Continue following the directions in the
“Belt replacement” section to replace
belt, new agitator, agitator cover and
hood.
Replace agitator cover (B) and 2
screws.
3-25
Replace hood, 2 screws and hose.
3-26
Raise nozzle up and replace the 2
screws on the bottom.
3-27
B
3-21
3-22
With lettering to the outside of belt, slide
new belt along side of cleaner cavity
and over motor pulley (C).
Insert agitator through belt and place
belt in belt guide (D).
D
C
3-23
Grasp agitator firmly and fit it into posi-
tion by first sliding end opposite the belt
into the rectangular slot (E) on side of
cleaner.
Pull other side of agitator (F) into place.
Turn agitator, making sure belt is not
pinched between agitator and cleaner
body. The belt must rotate freely inside
the belt guide. If the agitator does not
turn, reposition belt in the belt guide.
E