Hotpoint AH12H15D5B Installation Instructions - Page 6
USING THE AIR CONDITIONER, Dip Switch Configuration
View all Hotpoint AH12H15D5B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
USING THE AIR CONDITIONER S8 S7 S6 S5 S4 S3 S2 S1 S9 Dip Switch Configuration REMOVING THE FRONT PANEL Dip switch controls are located behind front panel, through an opening below the control panel. To access,remove front panel. 2. Then lift up Dip switches are accessible without opening the FRQWUROER[ 'LS6ZLWFKHV 1. 3XOORXWDWWKH bottom to release it from the tabs . Unit must be powered OFF to change dip switch settings. DIP SWITCHES CONFIGURATIONS 6HHWKHWDEOHDQGILJXUHEHORZIRU'LS6ZLWFK configurations and functions of each dip switch position. (Factory default switch positions (darkened portion) shown) 1 23 4 1 23 4 Do Not Adjust UP(ON) 1 2 1 2 3 4 DOWN(OFF) Heating type Temperature display type Control type Setpoint limit 1 Setpoint limit 2 Fan CON/CYC for heating Fan CON/CYC for cooling Low temp. Protection No. 6 6 6 6 6 6 6 6 DIP SWITCH CONFIGURATION TABLE UP (ON) DOWN (OFF) Remarks (OHFWULF+HDW2QO\ (OHFWULF+HDWDQG3XPS+HDW )RU+HDW3XPSXQLWRQO\ Temperature Display in F° Temperature Display in C° :DOO7KHUPRVWDW(QDEOH &RQWURO3DQHO(QDEOH 6Ÿ6 6Ÿ6 6ź6 6ź6 7ZRFRQILJXUDWLRQV6 6 FRPELQHWR select unit thermostat set point range. )DQ&RQWLQXRXV5XQIRU+HDWLQJ )DQ&\FOHIRU+HDWLQJ Fan Continuous Run for Cooling Fan Cycle for Cooling /RZWHPS3URWHFWLRQHQDEOH /RZWHPS3URWHFWLRQGLVDEOH 2SWLRQDO * NOTE: 7KHPD[LPXPWHPSHUDWXUHVHWWLQJLV)LQ FRROLQJDQG)LQKHDWLQJ Wall Thermostat Enable $ZDOOWKHUPRVWDWFDQEHFRQQHFWHGWRWKHXQLW,ILWLV GLSVZLWFK6PXVWEHPRYHGWRWKH:DOO7KHUPRVWDW (QDEOH3RVLWLRQ83 EHIRUHWKHZDOOWKHUPRVWDWZLOO control the unit. For proper wall thermostat operation, PDNHVXUHGLSVZLWFK6LVLQWKHGRZQSRVLWLRQ Low temp. Protection (optional) ,IXQLWVHQVHVDURRPWHPSHUDWXUHEHORZ)WKHLQGRRU fan motor and electric strip heat will turn on and warm the room to 40°F. The fan and heater will shut down a short time after the temperature is satisfied. Electric Heat Only (for heat pump unit only) 7KLVVHWWLQJLVW\SLFDOO\XVHGIRU(PHUJHQF\+HDWLQJ Heat and Cool Fan CON/CYC Dip-switches $OORZVWKHIDQWRRSHUDWHLQFRQWLQXRXVRUF\FOHPRGHV while the unit is in heating and cooling mode. CON(Continuous) $OORZVIDQWRUXQFRQWLQXRXVO\FLUFXODWLQJDLUHYHQ when the temperature setting has been satisfied. This switch helps to maintain the room temperature closer to the thermostat setting. CYC(Cycle) This setting allows the fan to cycle on and off with the compressor or electric heater. The fan stops a short time after the temperature setting is satisfied. Setpoint Temperature Limits 3URYLGHVDUHVWULFWHGUDQJHRIWHPSHUDWXUHFRQWURO 6 49-5000684 Rev. 1