Hoveround Prowler 4-Wheel Scooter User Manual - Page 20

Table 2: Scooter Controller Internal Diagnostics

Page 20 highlights

For service assistance, please call your authorized ActiveCare dealer. Table 2: Scooter Controller Internal Diagnostics Flash code Possible Cause 1 The battery needs charging. 2 Battery voltage is too low. 3 Battery voltage too high 4 Current limit time out Solution The battery voltage has dropped below 23.3 volts in neutral. Recharge batteries. The battery has dropped past 16.5 volts and is not sufficient to allow safe driving. Check the battery condition and the connections. The battery has exceeded 32 volts. Check the battery condition and the connections. The motor current has reached too high a value. Check the condition of the motor and loom. Contact your Service Agent. 5 Park brake fault Check park brake conditions. 6 Speed control out of neutral 7 Speed control fault Return speed pod to neutral and rest system. Readjust the speed lever to neutral if necessary. Contact your Service Agent. Check speed pod wiring for open or short circuits. Check speed pot set-up. Contact your Service Agent. 8 Motor fault Contact your Service Agent. 9 Internal (controller) fault Contact your Service Agent. 19 Prowler 3310/3410 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

For service assistance, please call your authorized ActiveCare dealer.
19
Prowler 3310/3410 Owner’s Manual
Table 2: Scooter Controller Internal Diagnostics
Flash
code
Possible Cause
Solution
1
The battery needs charging.
The battery voltage has dropped below
23.3 volts in neutral. Recharge
batteries.
2
Battery voltage is too low.
The battery has dropped past 16.5
volts and is not sufficient to allow safe
driving. Check the battery condition
and the connections.
3
Battery voltage too high
The battery has exceeded 32 volts.
Check the battery condition and the
connections.
4
Current limit time out
The motor current has reached too
high a value. Check the condition of
the motor and loom. Contact your
Service Agent.
5
Park brake fault
Check park brake conditions.
6
Speed control out of neutral
Return speed pod to neutral and rest
system. Readjust the speed lever to
neutral if necessary. Contact your
Service Agent.
7
Speed control fault
Check speed pod wiring for open or
short circuits. Check speed pot set-up.
Contact your Service Agent.
8
Motor fault
Contact your Service Agent.
9
Internal (controller) fault
Contact your Service Agent.