Hunter 23683 Owner's Manual - Page 5

For Angled Ceilings

Page 5 highlights

2 • Installing the Ceiling Plate 2-1. Drill two pilot holes into the wood support structure through the outermost holes in the outlet box. e pilot holes should be 9/64" in diameter. 2-2. Your fan comes with four neoprene noise isolators ("Isolators"). Position the isolators between the ceiling plate and ceiling by inserting the raised areas on each isolator into the holes in the ceiling plate. 2-3. read the lead wires from the outlet box down through the hole in the middle of the ceiling plate. 2-4. Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure. For proper alignment use slotted holes directly across from each other. Note: e isolators should be flush against the ceiling. 2-5. Place a flat washer on each of the two 3" screws and pass the screws through the slotted holes in the ceiling plate into the pilot holes you drilled. Tighten the screws into the 9/64" pilot holes; do not use lubricants on the screws. Do not over tighten. Isolator Ceiling Plate Step 2-2 5 Flat Washer Steps 2-3 - 2-5 3" Screw 41922-01 • 02/26/07 For Angled Ceilings: Be sure to orient the ceiling plate so that the arrows printed on the ceiling plate are pointing towards the ceiling peak. Hunter Fan Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

5
41922-01 • 02/2
6
/0
7
Hunter Fan Company
2 • Installing the Ceiling Plate
2-1. Drill two pilot holes into the wood support structure through the
outermost holes in the outlet box. e pilot holes should be 9/64”
in diameter.
2-2. Your fan comes with four neoprene noise isolators (“Isolators”).
Position the isolators between the ceiling plate and ceiling by
inserting the raised areas on each isolator into the holes in the
ceiling plate.
2-3. read the lead wires from the outlet box down through the hole
in the middle of the ceiling plate.
2-4. Align the slotted holes in the ceiling plate with the pilot holes you
drilled in the wood support structure. For proper alignment use
slotted holes directly across from each other.
Note:
e isolators should be flush against the ceiling.
2-5. Place a flat washer on each of the two 3” screws and pass the
screws through the slotted holes in the ceiling plate into the pilot
holes you drilled.
Tighten the screws into the 9/64” pilot holes; do not use lubricants
on the screws. Do not over tighten.
Step 2-2
Flat Washer
3” Screw
Steps 2-3 – 2-5
For Angled Ceilings:
Be sure to
orient the ceiling plate so that the
arrows printed on the ceiling plate are
pointing towards the ceiling peak.
Ceiling
Plate
Isolator