4 •Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician. Wall switches are not included. Select an acceptable general-use switch in accordance with national and local electrical codes. 4-1. Before attempting installation, make sure the power is still off. 4-2. To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist clockwise until tight. For all these connections use the wire connectors provided. 4-3. Connect the bare or green ground wire (grounding) from the ceiling to the green ground wire (grounding) from the ceiling plate and the green ground wire (grounding) from the fan. 4-4. Connect the white wire (grounded) from the ceiling to the white wire (grounded) from the fan. 4-5. Connect the remaining wires as follows: Dual Switch Wiring: • The black wire (ungrounded) from the ceiling to the black wire (ungrounded) from the fan • The black wire with a white stripe (ungrounded) from the fan to the wire (ungrounded) for the wall switch Single Switch Wiring: • The black wire (ungrounded) from the ceiling to the black (ungrounded) and the black wire with a white stripe (ungrounded) from the fan CAUTION: Be sure no bare wire or wire strands are visible after making connections. 4-6. Turn the splices upward and push them carefully back through the ceiling plate into the outlet box. 4-7. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box. Wire Connector 9 42884-01 • 11/05/09 • Hunter Fan Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

9
42884-01
11/05/09
Hunter Fan Company
All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualified electrician.
Wall switches are not included. Select an acceptable general-use switch
in accordance with national and local electrical codes.
4-1. Before attempting installation, make sure the power is still off.
4-2. To connect the wires, hold the bare metal leads together and place
a wire connector over them, then twist clockwise until tight. For
all these connections use the wire connectors provided.
4-3. Connect the bare or green ground wire (grounding) from the
ceiling to the green ground wire (grounding) from the ceiling plate
and the green ground wire (grounding) from the fan.
4-4. Connect the white wire (grounded) from the ceiling to the white
wire (grounded) from the fan.
4-5. Connect the remaining wires as follows:
Dual Switch Wiring:
• °e black wire (ungrounded) from the ceiling to the black wire
(ungrounded) from the fan
• °e black wire with a white stripe (ungrounded) from the fan
to the wire (ungrounded) for the wall switch
Single Switch Wiring:
• °e black wire (ungrounded) from the ceiling to the black
(ungrounded) and the black wire with a white stripe
(ungrounded) from the fan
CAUTION:
Be sure no bare wire or wire strands are visible after
making connections.
4-6. Turn the splices upward and push them carefully back through the
ceiling plate into the outlet box.
4-7. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the
outlet box.
Wire
Connector