Husqvarna AUTOMOWER 315X Owner Manual - Page 21

Installation of the product, To install the charging station, To install the boundary wire - canada

Page 21 highlights

3.4 Installation of the product 3.4.1 To install the charging station WARNING: Obey national regulations about electrical safety. 1. Read and understand the instructions about the charging station. Refer to To examine where to put the charging station on page 16. 2. Put the charging station in the selected area. 3. Connect the low-voltage cable to the charging station. 4. Put the power supply at a minimum height of 30 cm / 12 in. weatherproof with the attachment plug cap inserted or removed. 6. Put the low-voltage cable in the ground with stakes or bury the cable. Refer to To put the wire into position with stakes on page 22 or To bury the boundary wire or the guide wire on page 22. 7. Connect the wires to the charging station. Refer to To install the boundary wire on page 21 and To install the guide wire on page 22. 8. Attach the charging station to the ground with the supplied screws. CAUTION: Do not make new holes in the charging station plate. min 30 cm / 12" CAUTION: The product is only to be used with the power supply unit supplied by Husqvarna. WARNING: Do not put the power supply at a height where there is a risk it can be put in water. Do not put the power supply on the ground. CAUTION: Do not put your feet on the charging station. 3.4.2 To install the boundary wire 1. Put the boundary wire around all of the work area. Start and complete the installation behind the charging station. CAUTION: Do not put unwanted wire in a coil. The coil causes interference with the product. 2. Open the connector and put the boundary wire in the connector. WARNING: Do not encapsulate the power supply. Condensed water can harm the power supply and increase the risk of electrical shock. 5. Connect the power supply cable to a 100-240V outdoor power outlet. WARNING: Applicable to USA/ Canada. If power supply is installed outdoors: Risk of Electric Shock. Install only to a covered Class A GFCI receptacle (RCD) that has an enclosure that is 3. Close the connector with a pair of pliers. 4. Cut the boundary wire 1-2 cm / 0.4-0.8 in. above each connector. 5. Put the right end of boundary wire into the channel with the mark "AR". 6. Put the left end of boundary wire into the channel with the mark "AL". 7. Push the right connector onto the metal pin on the charging station with the mark "AR". 1220 - 001 - 08.07.2019 Installation - 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

3.4 Installation of the product
3.4.1 To install the charging station
WARNING:
Obey national regulations
about electrical safety.
1.
Read and understand the instructions about
the charging station. Refer to
To examine
where to put the charging station on page
16
.
2.
Put the charging station in the selected area.
3.
Connect the low-voltage cable to the
charging station.
4.
Put the power supply at a minimum height of
30 cm / 12 in.
min 30 cm / 12”
CAUTION:
The product is only to
be used with the power supply
unit supplied by Husqvarna.
WARNING:
Do not put the power
supply at a height where there is a
risk it can be put in water. Do not
put the power supply on the
ground.
WARNING:
Do not encapsulate
the power supply. Condensed
water can harm the power supply
and increase the risk of electrical
shock.
5.
Connect the power supply cable to a
100-240V outdoor power outlet.
WARNING:
Applicable to USA/
Canada. If power supply is
installed outdoors: Risk of Electric
Shock. Install only to a covered
Class A GFCI receptacle (RCD)
that has an enclosure that is
weatherproof with the attachment
plug cap inserted or removed.
6.
Put the low-voltage cable in the ground with
stakes or bury the cable. Refer to
To put the
wire into position with stakes on page 22
or
To bury the boundary wire or the guide wire
on page 22
.
7.
Connect the wires to the charging station.
Refer to
To install the boundary wire on
page 21
and
To install the guide wire on
page 22
.
8.
Attach the charging station to the ground
with the supplied screws.
CAUTION:
Do not make new
holes in the charging station plate.
CAUTION:
Do not put your feet on
the charging station.
3.4.2 To install the boundary wire
1.
Put the boundary wire around all of the work
area. Start and complete the installation
behind the charging station.
CAUTION:
Do not put unwanted
wire in a coil. The coil causes
interference with the product.
2.
Open the connector and put the boundary
wire in the connector.
3.
Close the connector with a pair of pliers.
4.
Cut the boundary wire 1-2 cm / 0.4-0.8 in.
above each connector.
5.
Put the right end of boundary wire into the
channel with the mark "AR".
6.
Put the left end of boundary wire into the
channel with the mark "AL".
7.
Push the right connector onto the metal pin
on the charging station with the mark "AR".
1220 - 001 - 08.07.2019
Installation -
21