6.3 Information messages Below a number of information messages are listed which may be shown in the product display. Contact your local Husqvarna representative if the same message appears often. Message Low battery Cause The product cannot find the charging station. Action Check that the charging station and the guide wire are installed in accordance with the instructions. Refer to To install the guide wire on page 22. The guide wire is broken or not connec- Find out where the break is and rectify ted. it. The battery is spent. Replace the battery. Refer to Battery on page 39. The charging station's antenna is defective. Check if the indicator lamp in the charging station flashes red. Refer to Indicator lamp in the charging station on page 47. Settings restored Confirmation that a Reset all user set- This is normal. No action required. tings has been carried out. Guide not found The guide wire is not connected to the charging station. Check that the guide wire's connector is tightly connected to the charging station. Refer to To install the guide wire on page 22. Break in the guide wire. Find out where the break is. Replace the damaged section of the guide wire with a new loop wire and splice using an original coupler. The guide wire is not connected to the boundary loop. Check that the guide wire is connected correctly to the boundary loop. Refer to To install the guide wire on page 22. Guide calibration failed The product has failed to calibrate the guide wire. Check that the guide wires are installed according to the instructions. Refer to To install the guide wire on page 22. Guide calibration The product has succeeded to calibrate No action required. accomplished the guide wire. Difficult finding home The product has been following the The installation has not been done cor- boundary wire several laps without find- rectly. Refer to To examine where to ing the charging station. put the boundary wire on page 17. Wrong corridor width setting on boundary wire. Refer to To set the corridor width of the boundary wire on page 19. The product was started on a Secondary area with the Main area setting. 46 - Troubleshooting 1220 - 001 - 08.07.2019

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

6.3 Information messages
Below a number of information messages are listed which may be shown in the product display.
Contact your local Husqvarna representative if the same message appears often.
Message
Cause
Action
Low battery
The product cannot find the charging
station.
Check that the charging station and the
guide wire are installed in accordance
with the instructions. Refer to
To install
the guide wire on page 22
.
The guide wire is broken or not connec-
ted.
Find out where the break is and rectify
it.
The battery is spent.
Replace the battery. Refer to
Battery
on page 39
.
The charging station’s antenna is de-
fective.
Check if the indicator lamp in the
charging station flashes red. Refer to
Indicator lamp in the charging station
on page 47
.
Settings restored
Confirmation that a
Reset all user set-
tings
has been carried out.
This is normal. No action required.
Guide not found
The guide wire is not connected to the
charging station.
Check that the guide wire’s connector
is tightly connected to the charging sta-
tion. Refer to
To install the guide wire
on page 22
.
Break in the guide wire.
Find out where the break is. Replace
the damaged section of the guide wire
with a new loop wire and splice using
an original coupler.
The guide wire is not connected to the
boundary loop.
Check that the guide wire is connected
correctly to the boundary loop. Refer to
To install the guide wire on page 22
.
Guide calibration
failed
The product has failed to calibrate the
guide wire.
Check that the guide wires are installed
according to the instructions. Refer to
To install the guide wire on page 22
.
Guide calibration
accomplished
The product has succeeded to calibrate
the guide wire.
No action required.
Difficult finding
home
The product has been following the
boundary wire several laps without find-
ing the charging station.
The installation has not been done cor-
rectly. Refer to
To examine where to
put the boundary wire on page 17
.
Wrong corridor width setting on boun-
dary wire. Refer to
To set the corridor
width of the boundary wire on page 19
.
The product was started on a Secon-
dary area with the Main area setting.
46
- Troubleshooting
1220 - 001 - 08.07.2019