APA Display SurePOS 500-XX3 supports an external all points addressable customer display. This is intended to meet Technology Brightness Vacuum Fluorescent 300 cd/m2 Format (dot) 160 x 40 Active Area (mm) 132.55 x 32.95 Dot Size (mm) 0.58 (W) x 0.58 (H) Dot Pitch (mm) 0.83 (W) x 0.83 (H) Display Color Green (peak wavelength 505 nm) Modes All Points Addressable (160x40) Character Mode Built in Font Code Pages for Character Mode Futaba Standard 5x7 A/N (4 and 5 line mode) IBM Code Page 437 modified 8x16 A/N English (2 line mode) Futaba Standard 8x16 A/N Katakana (2 line mode) JIS X 208-1990 16x16 Kanji (2 line mode) KS C 5601-1992 16x16 Hanguel (2 line mode) GB-2321-80 16x16 Simplified Chinese (2 line BIG5 mode) 16x16 Traditional Chinese (2 line mode) Character Box Height (mm) 5x7 3.90 (H) x 5.56 (W) 8x16 6.39 (H) x 13.03 (W) 16x16 13.03 (H) x 13.03 (W) Electrical Interface RS232 with 12 V power Power Consumption 6W (typ) 8.4 (max) Adjustment Multiposition Attachment Cable 3.8m DBCS language requirements. It attaches to the SurePOS 500-XX3 external customer display port which provides power and signal. .1 Software Description Boot Control The following boot options are available: LAN RPL - PXE 2.0 and IBM RPL only. External Diskette Drive (standard or USB) USB CD ROM Hard Disk Drive SurePOS 500 Model XX3 Technical Reference, v 1.3 81 Page 30 of