IBM NB1003 Hardware Maintenance Manual - Page 47
Checking, backup, battery
UPC - 890552502493
View all IBM NB1003 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
Checkout guide Note: Recharging will take at least 3 hours, even if the indicator does not turn on. If the voltage is still less than +11.0 V dc after recharging, replace the battery. 4. If the voltage is more than +11.0 V dc, measure the resistance between battery terminals 4 and 5. The resistance must be 4 to 30 K . If the resistance is not correct, replace the battery pack. If the resistance is correct, replace the system board. Checking the backup battery Do the following: 1. Power off the computer, and unplug the ac adapter from it. 2. Turn the computer upside down. 3. Remove the battery pack (see "1010 Battery pack for 14.1-in. LCD models" on page 71). 4. Remove the backup battery (see "Checking the battery pack" on page 40). 5. Measure the voltage of the backup battery. See the following figure. Red (+) Black (-) Wire Red Black Voltage (V dc) +2.5 to +3.2 Ground v If the voltage is correct, replace the system board. v If the voltage is not correct, replace the backup battery. v If the backup battery discharges quickly after replacement, replace the system board. General descriptions 41