11 TROUBLESHOOTING Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION REF. The transceiver does ••The battery is exhausted. ••Recharge the battery pack. p. 6 not turn ON. ••The battery pack is not correctly attached. ••Correctly reattach the battery pack. p. 2 ••The CP-23L's fuse is blown. ••Repair the problem, and then replace p. 18 the fuse. Little or no sound ••Squelch level is set too high. ••Adjust the squelch level. p. 4 comes from the ••Volume level is set too low. ••Adjust the volume level. p. 4 speaker. You cannot transmit. ••NAV band frequency is set. ••Weather channel or other nontransmittable channel is selected. ••No frequency is entered into the selected channel. ••The battery is exhausted. You cannot use the ••The keypad is locked. keypad to enter the frequency or select the memory channel. ••Set a COM band frequency. p. 7 ••Select a transmittable channel. p. 7 ••Enter a frequency into the Memory p. 9 channel. ••Recharge the battery pack. p. 6 ••Hold down [ ] for 2 seconds to p. 4 unlock the keypad. Scan does not start. No beep sounds. ••No Memory channels in the selected group are tagged. ••The squelch is open. ••Nothing is entered in the Memory channels. ••The Key beep is set to OFF. ••The audio output level is low. ••Tag memory channels. p. 8 ••Adjust the squelch level. p. 4 ••Enter frequencies into the Memory p. 9 channels. ••Push [FUNC], and then push p. 4 [8]/[BEEP] to turn ON the beep. ••Rotate [VOL] to adjust the audio p. 4 output level. DDFuse replacement If the fuse blows or the transceiver stop working when using the optional CP-23L CIGARETTE LIGHTER CABLE, correct the source of the problem. Then replace the damaged fuse with a new rated one (FGB 4 A), as shown to the right. Fuse 4 A 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

18
11
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
The transceiver does
not turn ON.
• The battery is exhausted.
• The battery pack is not correctly attached.
• The CP-23L’s fuse is blown.
• Recharge the battery pack.
• Correctly reattach the battery pack.
• Repair the problem, and then replace
the fuse.
p. 6
p. 2
p. 18
Little or no sound
comes from the
speaker.
• Squelch level is set too high.
• Volume level is set too low.
• Adjust the squelch level.
• Adjust the volume level.
p. 4
p. 4
You cannot transmit.
• NAV band frequency is set.
• Weather channel or other non-
transmittable channel is selected.
• No frequency is entered into the
selected channel.
• The battery is exhausted.
• Set a COM band frequency.
• Select a transmittable channel.
• Enter a frequency into the Memory
channel.
• Recharge the battery pack.
p. 7
p. 7
p. 9
p. 6
You cannot use the
keypad to enter the
frequency or select
the memory channel.
• The keypad is locked.
• Hold down [
] for 2 seconds to
unlock the keypad.
p. 4
Scan does not start.
• No Memory channels in the selected
group are tagged.
• The squelch is open.
• Nothing is entered in the Memory
channels.
• Tag memory channels.
• Adjust the squelch level.
• Enter frequencies into the Memory
channels.
p. 8
p. 4
p. 9
No beep sounds.
• The Key beep is set to OFF.
• The audio output level is low.
• Push [FUNC], and then push
[8]/[BEEP] to turn ON the beep.
• Rotate [VOL] to adjust the audio
output level.
p. 4
p. 4
D
Fuse replacement
If the fuse blows or the transceiver stop working when using
the optional CP-23L CIGARETTE LIGHTER CABLE, correct
the source of the problem. Then replace the damaged fuse
with a new rated one (FGB 4 A), as shown to the right.
Fuse 4 A