Icom IC-M604A Service Manual - Page 17

Pll Adjustments, Adjustment, Adjustment Condition, Measurement, Value, Point, Location, Adjust

Page 17 highlights

5-2 PLL ADJUSTMENTS ADJUSTMENT ADJUSTMENT CONDITION LOCK VOLTAGE 1 • Operating channel : ch P2 • Receiving 2 • Operating channel : ch P2 • Output power : Low • Transmitting 3 • Operating channel : ch 70 • Receiving MEASUREMENT UNIT LOCATION MAIN Connect a digital multi-meter or oscilloscope to check point CP1. Connect a digital multi-meter or oscilloscope to check point CP2. VALUE 3.8 V - 4.0 V 3.1 V - 3.3 V 2.4-3.7 V ADJUSTMENT POINT UNIT ADJUST MAIN L62 L73 Verify • MAIN UNIT TOP VIEW CP1 Lock voltage check point for RX L62 Lock voltage adjustment for RX L73 Lock voltage adjustment for TX CP2 Lock voltage check point for TX 5 - 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

• MAIN UNIT TOP VIEW
Lock voltage
adjustment for TX
L73
Lock voltage
check point for RX
CP1
Lock voltage
check point for TX
CP2
Lock voltage
adjustment for RX
L62
5-2 PLL ADJUSTMENTS
LOCK
VOLTAGE
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
1
2
3
• Operating channel : ch P2
• Receiving
• Operating channel : ch P2
• Output power
: Low
• Transmitting
• Operating channel : ch 70
• Receiving
MAIN
Connect a digital
multi-meter or oscil-
loscope to check
point CP1.
Connect a digital
multi-meter or oscil-
loscope to check
point CP2.
3.8 V – 4.0 V
3.1 V – 3.3 V
2.4–3.7 V
MAIN
L62
L73
Verify
5 - 2