Icom IC-R75 Instruction Manual - Page 39

UT-106, Optional IF filters

Page 39 highlights

10 OPTION INSTALLATIONS ■ UT-106 d sp unit The UT-106 provides AF DSP functions such as noise reduction and auto notch. q R emove the top and bottom covers. w R emove the shielding plate. e R emove the connection cable (P1241) from J1221 on the MAIN unit. Connect the cable into J1 on the UT-106. r P lug the connection cable (P1) from the UT-106 to J1221 on the MAIN unit. t P lug the flat cable into J3 on the UT-106 and to J1231 on the MAIN unit. • Take care of the conductor direction. y A ttach the Velcro tape as shown at right. Attach the UT-106 to the reverse side of the MAIN unit. u R eturn the shielding plate, top cover and bottom cover to their original positions. UT-106 P1241 J3 P1241 J1231 J1221 ■ Optional IF filters Several IF filters are available for the IC-R75. You can install 1 filter for both 9 MHz and 455 kHz IF. Choose appropriate filter for your operating needs. 9 MHz optional filters: FL-101 cw narrow filter FL-232 rtty/cw narrow filter FL-100 cw narrow filter FL-223 ssb narrow filter FL-103 ssb wide filter 250 Hz/-6 dB 350 Hz/-6 dB 500 Hz/-6 dB 1.9 kHz/-6 dB 2.8 kHz/-6 dB 455 kHz optional filters: FL-53A cw narrow filter FL-52A cw/rtty narrow filter FL-222 ssb narrow filter FL-96 ssb wide filter FL-257 ssb wide filter 250 Hz/-6 dB 500 Hz/-6 dB 1.8 kHz/-6 dB 2.8 kHz/-6 dB 3.3 kHz/-6 dB 9 MHz filter D Installation q R emove the top cover as shown on the opposite page. w Install the desired 9 MHz filter as shown in the diagram below. • The filters can be installed in either direction. e Install the desired 455 kHz filter as shown in the diagram below. r Replace the top cover. After filter installation, specify the installed filter using filter set mode. (p. 19) Otherwise, the installed filter will not function properly. 455 kHz filter 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

35
10
OPTION INSTALLATIONS
UT-106
DSP
UNIT
Optional IF filters
The UT-106 provides AF DSP functions such as
noise reduction and auto notch.
q
Remove the top and bottom covers.
w
Remove the shielding plate.
e
Remove the connection cable (P1241) from
J1221 on the MAIN unit. Connect the cable into
J1 on the UT-106.
r
Plug the connection cable (P1) from the UT-106
to J1221 on the MAIN unit.
t
Plug the flat cable into J3 on the UT-106 and to
J1231 on the MAIN unit.
• Take care of the conductor direction.
y
Attach the Velcro tape as shown at right. Attach
the UT-106 to the reverse side of the MAIN unit.
u
Return the shielding plate, top cover and bottom
cover to their original positions.
UT-106
P1241
P1241
J1221
J1231
J3
Several IF filters are available for the IC-R75. You
can install 1 filter for both 9 MHz and 455 kHz IF.
Choose appropriate filter for your operating needs.
9 MHz optional filters:
FL-101
CW
NARROW
FILTER
250 Hz/–6 dB
FL-232
RTTY
/
CW
NARROW
FILTER
350 Hz/–6 dB
FL-100
CW
NARROW
FILTER
500 Hz/–6 dB
FL-223
SSB
NARROW
FILTER
1.9 kHz/–6 dB
FL-103
SSB
WIDE
FILTER
2.8 kHz/–6 dB
455 kHz optional filters:
FL-53A
CW
NARROW
FILTER
250 Hz/–6 dB
FL-52A
CW
/
RTTY
NARROW
FILTER
500 Hz/–6 dB
FL-222
SSB
NARROW
FILTER
1.8 kHz/–6 dB
FL-96
SSB
WIDE
FILTER
2.8 kHz/–6 dB
FL-257
SSB
WIDE
FILTER
3.3 kHz/–6 dB
D
Installation
q
Remove the top cover as shown on the opposite
page.
w
Install the desired 9 MHz filter as shown in the
diagram below.
• The filters can be installed in either direction.
e
Install the desired 455 kHz filter as shown in the
diagram below.
r
Replace the top cover.
After filter installation, specify the installed filter
using filter set mode. (p. 19) Otherwise, the
installed filter will not function properly.
9 MHz filter
455 kHz filter