Icom VE-PG4 Precautions - Page 2

Disposal, Fcc Information, Supplied Accessories, Dimensions, About Ce, Connection

Page 2 highlights

PRECAUTIONS (Continued) ■ For the AC adapter R WARNING! NEVER use other than the RoIP Gateway. This may result in an electrical shock, cause a fire or damage the AC adapter. R WARNING! Connect the adapter into an outlet between 100 V and 240 V AC. Otherwise, this may result in an electrical shock, cause a fire or damage the AC adapter. R WARNING! NEVER install the AC adapter to wet place where is outside or near the humidifier. This may result in an electrical shock, cause a fire or damage the AC adapter. R WARNING! NEVER put something heavy on the AC adapter cable. This may result in an electrical shock, cause a fire or damage the AC adapter. R WARNING! NEVER modify, bend by force, twist, pull or heat the AC adapter's cable. This may result in an electrical shock, cause a fire or damage the AC adapter. R WARNING! NEVER touch the AC adapter with wet hands. This may result in an electrical shock or damage the AC adapter. R WARNING! NEVER use the AC adapter when it can not closely insert into the AC outlet. This may result in an electrical shock, cause a fire or damage the AC adapter. R WARNING! Use and place the AC adapter and connection cable to avoid inadvertent use by children. This may result in an electrical shock or cause injury. ■ Other precautions • When operating the PC or external device, see those instruction manuals for details. • The supplied AC adapter may at some time need to be replaced, depending on its life expectancy. The life of an AC adaptor differs according to the environment or condition in which the adaptor is used. W e recommend replacement when it has been used for approximately 5 years (When used under the ambient temperature of 25 °C: 77°F). Contact your local dealer for details. • RoIP Gateway supports only IPv4. IPv6 is not supported. FCC INFORMATION CAUTION: Changes or modifications to this equipment, not expressly approved by the Icom Inc., could void your authority to operate this equipment under FCC regulations. • FOR CLASS B UNINTENTIONAL RADIATORS: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. ABOUT CE Hereby, Icom Inc. declares that the versions of VE-PG4 which have the "CE" symbol on the product, comply with the essential requirements of the Radio Equipment Directive, 2014/53/ EU, and the restriction of the use of certain hazardous substances in electrical and electronic equipment Directive, 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.icom.co.jp/world/support DISPOSAL The crossed-out wheeled-bin symbol on your product, literature, or packaging reminds you that in the European Union, all electrical and electronic products, batteries, and accumulators (rechargeable batteries) must be taken to designated collection locations at the end of their working life. Do not dispose of these products as unsorted municipal waste. Dispose of them according to the laws in your area. - 2 - SUPPLIED ACCESSORIES • Power adapter...... 1 • Clamp 1 • Magnet legs......... 4 • Screws 4 • Connectors......... 24 • Cushion sheet 1 • Antennas 2 • Antenna mount base...... 2 • This leaflet LL Refer to the web manual for transceivers and cables that are usable with the RoIP Gateway. About the antenna mount base Use the supplied antenna mount base to place the antenna into a better location. • Attach the mount base to a steel rack using the magnet on the bottom side. Refer to the web manual for details. Approximately 1.5 m (4 /15 16 feet) 41 mm (1 5/8 inch) 310 mm (12 7/32 inch) 270 mm (10 5/8 inch) DIMENSIONS 213 mm (8 3/8 inch) 221 mm (8 23/32) 36.8 mm (1 7/16) CONNECTION Disconnect the PC from the network, before connecting cables. Attach antennas for 4G/3G communication 2 antennas (Supplied) Turn clockwise t Verify the indications Check the LAN cable connection if no indicators light. qw Lights: Connected Blinks: Communicating q green:1000BASE-T w orange: 10BASE-T/100BASE-TX qAttach cushions on the bottom panel Cushions (Supplied) To attach supplied magnet legs, refer to the web manual for details. VE-PG4 (Default: 192.168.0.1) w Connect cables LAN cable (User supplied) (Category 5e or higher) Use the supplied clamp to fix the power cable to the ground terminal. Ground terminal Power cable Clamp (Supplied) Grounding wire (User supplied) e Connect the power supply AC outlet The [PWR] indicator on the front panel lights Ground terminal To tThoetThoeGtr[hoLeuAnDN]dCptjoaerrctkminal PC (Example: 192.168.0.100) r Boot the PC IP address for PC The RoIP Gateway's IP address is set to "192.168.0.1," and the DHCP server to "Disable" as the defaults. Set the PC's IP address in the 192.168.0.x network (Example: "192.168.0.100"). See the PC's instruction manual for the IP address setting details. Power adapter* (Supplied) *Shape may differ. Grounding wire (User supplied) RWARNING! To prevent electrical shock, television interference (TVI), broadcast interference (BCI) and other problems, ground the RoIP Gateway through the ground terminal. NEVER connect the ground terminal to a gas or electric pipe. This may result in an electrical shock, or cause a fire. - 3 -

  • 1
  • 2

2
3
For the AC adapter
R
WARNING! NEVER
use other than the RoIP Gateway.
This may result in an electrical shock, cause a fire or
damage the AC adapter.
R
WARNING!
Connect the adapter into an outlet
between 100 V and 240 V AC. Otherwise, this may result in
an electrical shock, cause a fire or damage the AC adapter.
R
WARNING! NEVER
install the AC adapter to wet place
where is outside or near the humidifier. This may result in an
electrical shock, cause a fire or damage the AC adapter.
R
WARNING! NEVER
put something heavy on the AC
adapter cable. This may result in an electrical shock,
cause
a fire or damage the AC adapter.
R
WARNING! NEVER
modify, bend by force, twist,
pull or heat the AC adapter’s cable. This may result in an
electrical shock, cause a fire or damage the AC adapter.
R
WARNING! NEVER
touch the AC adapter with wet
hands. This may result in an electrical shock or damage the
AC adapter.
R
WARNING! NEVER
use the AC adapter when it can
not closely insert into the AC outlet. This may result in an
electrical shock, cause a fire or damage the AC adapter.
R
WARNING!
Use and place the AC adapter and
connection cable to avoid inadvertent use by children. This
may result in an electrical shock or
cause injury
.
Other precautions
• When operating the PC or external device, see those
instruction manuals for details.
• The supplied AC adapter may at some time need to be
replaced, depending on its life expectancy. The life of
an AC adaptor differs according to the environment or
condition in which the adaptor is used.
We recommend replacement when it has been used for
approximately 5 years (When used under the ambient
temperature of 25 °C: 77°F). Contact your local dealer for
details.
• RoIP Gateway supports only IPv4. IPv6 is not supported.
The crossed-out wheeled-bin symbol on your
product, literature, or packaging reminds you
that in the European Union, all electrical and
electronic products, batteries, and accumula-
tors (rechargeable batteries) must be taken to
designated collection locations at the end of
their working life. Do not dispose of these products as
unsorted municipal waste.
Dispose of them according to the laws in your area.
DISPOSAL
PRECAUTIONS (Continued)
FCC INFORMATION
SUPPLIED ACCESSORIES
DIMENSIONS
ABOUT CE
CONNECTION
Hereby, Icom Inc. declares that the versions
of VE-PG4 which have the “CE” symbol
on the product, comply with the essential
requirements of the Radio Equipment Directive, 2014/53/
EU, and the restriction of the use of certain hazardous
substances in electrical and electronic equipment Directive,
2011/65/EU.
The full text of the EU declaration of conformity is available
at the following internet address:
CAUTION: Changes or modifications to this equipment,
not expressly approved by the Icom Inc.,
could void your authority to operate this
equipment under FCC regulations.
• FOR CLASS B UNINTENTIONAL RADIATORS:
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
• Power adapter … 1
• Cushion sheet …………1
• Clamp …………… 1
• Antennas ………………2
• Magnet legs …… 4
• Antenna mount base …2
• Screws …………… 4
• This leaflet
• Connectors ……
24
L
Refer to the web manual for transceivers and cables that are
usable with the RoIP Gateway.
Disconnect the PC from the network, before connecting cables.
IP address for PC
The RoIP Gateway’s IP address is set to “192.168.0.1,”
and the DHCP server to “Disable” as the defaults. Set the
PC's IP address in the 192.168.0.x network (Example:
“192.168.0.100”).
See the PC’s instruction manual for the IP address setting
details.
About the antenna mount base
Use the supplied antenna mount
base to place the antenna into a
better location.
• Attach the mount base to a steel
rack using the magnet on the bot-
tom side. Refer to the web manual
for details.
41 mm (1
5
/
8
inch)
Approximately
1.5 m (4
15
/
16
feet)
36.8 mm (1
7
/
16
)
213 mm (8
3
/
8
inch)
310 mm (12
7
/
32
inch)
270 mm (10
5
/
8
inch)
221 mm (8
23
/
32
)
R
WARNING!
To prevent electrical shock, television interference (TVI),
broadcast interference (BCI) and other problems, ground the
RoIP Gateway through the ground terminal.
NEVER
connect the ground terminal to a gas or electric pipe.
This may result in an electrical shock, or cause a fire.
To the DC jack
To the [LAN] port
To the Ground terminal
LAN cable (User supplied)
(Category 5e or higher)
Grounding wire
(User supplied)
Power adapter*
(Supplied)
AC outlet
PC
(Example: 192.168.0.100)
Ground terminal
*Shape may differ.
Verify the indications
t
Check the LAN cable connection if no indicators light.
Use the supplied clamp to fix the power
cable to the ground terminal.
Clamp
(Supplied)
Power cable
Power cable
Ground terminal
Grounding wire
(User supplied)
w
q
Lights: Connected
Blinks: Communicating
q
green: 1000BASE-T
w
orange: 10BASE-T/100BASE-TX
w
q
Connect cables
Connect cables
Connect the power supply
e
Boot the PC
r
The [PWR] indicator on
the front panel lights
The [PWR] indicator on
the front panel lights
VE-PG4
(Default: 192.168.0.1)
Attach cushions on the bottom panel
Cushions
(Supplied)
To attach supplied magnet legs, refer to the web
manual for details.
Attach antennas for 4G/3G communication
2 antennas
(Supplied)
2 antennas
(Supplied)
Turn clockwise