Insignia NS-AC08PWH1 User Guide - Page 28

Error codes, Specifications, Legal notices, FCC Part 15, FCC Warning

Page 28 highlights

Portable Air Conditioner Error codes Your air conditioner displays error and protection codes on the control panel display to help you resolve problems. Note: When an error occurs, turn off your air conditioner, check for obstructions, then turn it back on. If the error reoccurs, turn off and unplug your air conditioner. Contact a qualified technician for service. ERROR CODE DESCRIPTION E1 Room temperature sensor error. E2 Evaporator temperature sensor error. E3 Condenser temperature sensor error. E4 Display panel communication error. EC Refrigerant leakage detection malfunction. P1 Bottom tray is full. Connect the drain hose and drain the collected water away. See Emptying the drain tray on page 26. Specifications Specifications are subject to change without notice. Dimensions (W × D × H) Weight 27.5 H × 17.8 W × 14.3 D in. (70 × 45.4 × 36.5 cm) NS-AC06PWH1 (6,000 BTU): 59 lbs. (26.8 kg) NS-AC07PWH1 (7,000 BTU): 61.9 lbs. (28.1 kg) NS-AC08PWH1 (8,000 BTU): 68.1 lbs (30.9 kg) Operating temperature range 62° to 86° F (17° to 30° C) Power requirements AC115 V ~ 60 Hz Power cord length 74.8 in. (1.9 m) Legal notices FCC Part 15 This device complies with Part 15 of the FCC Rules. Operation of this product is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply within the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced technician for help. FCC Warning Changes or modifications not expressly approved by the party responsible for compliance with the FCC Rules could void the user's authority to operate this equipment. 28 www.insigniaproducts.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

www.insigniaproducts.com
28
Portable Air Conditioner
Error codes
Your air conditioner displays error and protection codes on the control panel display to help you resolve problems.
Specifications
Specifications are subject to change without notice.
Legal notices
FCC Part 15
This device complies with Part 15 of the FCC Rules. Operation of this product is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply within the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced technician for help.
FCC Warning
Changes or modifications not expressly approved by the party responsible for compliance with the FCC Rules could void the user’s authority to operate
this equipment.
Note:
When an error occurs, turn off your air conditioner, check for obstructions, then turn it back on. If the error reoccurs, turn off and
unplug your air conditioner. Contact a qualified technician for service.
ERROR CODE
DESCRIPTION
E1
Room temperature sensor error.
E2
Evaporator temperature sensor error.
E3
Condenser temperature sensor error.
E4
Display panel communication error.
EC
Refrigerant leakage detection malfunction.
P1
Bottom tray is full. Connect the drain hose and
drain the collected water away. See Emptying the
drain tray
on page 26
.
Dimensions (W × D × H)
27.5 H × 17.8 W × 14.3 D in. (70 × 45.4 × 36.5 cm)
Weight
NS-AC06PWH1 (6,000 BTU): 59 lbs. (26.8 kg)
NS-AC07PWH1 (7,000 BTU): 61.9 lbs. (28.1 kg)
NS-AC08PWH1 (8,000 BTU): 68.1 lbs (30.9 kg)
Operating temperature range
62° to 86° F (17° to 30° C)
Power requirements
AC115 V ~ 60 Hz
Power cord length
74.8 in. (1.9 m)