Intel AXXRMS2AF080 Hardware User Guide - Page 14

Redundancy and Error Handling, Failures are logged in NVRAM, viewable from OS Event Log, Intel - firmware

Page 14 highlights

- No reboot necessary after expansion - Load Balancing • Upgradeable Flash ROM interface. • Allows for staggered spin-up, hot-plug, and lower power consumption. • User specified rebuild rate (percent of system resources to use from 0-100%). Caution: Exceeding 50% rate may cause operating system errors due to waiting for controller access. • Background operating mode can be set for Rebuilds, Consistency Checks, Initialization (auto restarting Consistency Check on redundant volumes), Migration, OCE, and Patrol Read. Redundancy and Error Handling • SGPIO, In-band and out-band SES2 Enclosure management support. • Drive coercion (auto-resizing to match existing disks). • Auto-detection of failed drives with transparent rebuild. There must be disk activity (I/O to the drive) for a missing drive to be marked as failed. • Auto-resume on reboot of initialization or rebuild (must be enabled before virtual disk creation). • Smart initialization automatically checks consistency of virtual disks if there are five or more disks in a RAID 5 array, which optimizes performance by enabling readmodify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode. • Smart Technology predicts failures of drives and electronic components. • Patrol Read checks drives and maps bad sectors. • Commands are retried at least four times. • Firmware provides best effort to recognize an error and recover if possible. • Failures are logged from controller and drive firmware, and SMART monitor. • Failures are logged in NVRAM, viewable from OS Event Log, Intel® RAID Web Console 2; CIM, LEDs. • Access policy: - RW: allow read and write I/O - Read Only: allow read I/O only - Blocked: deny read and write I/O • Redundancy through: - Configuration stored in non-volatile RAM and on the drives (COD). - Hot-swap support. 4 Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

4
Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide
No reboot necessary after expansion
Load Balancing
Upgradeable Flash ROM interface.
Allows for staggered spin-up, hot-plug, and lower power consumption.
User specified rebuild rate (percent of system resources to use from 0-100%).
Caution:
Exceeding 50% rate may cause operating system errors due to waiting for
controller access.
Background operating mode can be set for Rebuilds, Consistency Checks,
Initialization (auto restarting Consistency Check on redundant volumes), Migration,
OCE, and Patrol Read.
Redundancy and Error Handling
SGPIO, In-band and out-band SES2 Enclosure management support.
Drive coercion (auto-resizing to match existing disks).
Auto-detection of failed drives with transparent rebuild. There must be disk activity
(I/O to the drive) for a missing drive to be marked as failed.
Auto-resume on reboot of initialization or rebuild (must be enabled before virtual
disk creation).
Smart initialization automatically checks consistency of virtual disks if there are five
or more disks in a RAID 5 array, which optimizes performance by enabling read-
modify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode.
Smart Technology predicts failures of drives and electronic components.
Patrol Read checks drives and maps bad sectors.
Commands are retried at least four times.
Firmware provides best effort to recognize an error and recover if possible.
Failures are logged from controller and drive firmware, and SMART monitor.
Failures are logged in NVRAM, viewable from OS Event Log, Intel
®
RAID Web
Console 2; CIM, LEDs.
Access policy:
RW: allow read and write I/O
Read Only: allow read I/O only
Blocked: deny read and write I/O
Redundancy through:
Configuration stored in non-volatile RAM and on the drives (COD).
Hot-swap support.