Intel H2000 Technical Product Specification - Page 65

BMC Basic and Advanced Management Features

Page 65 highlights

Intel® Server Board S2600JF TPS Platform Management Functional Overview a. Receiving a Chassis Control command to pulse the diagnostic interrupt. This command does not cause an event to be logged in the SEL. b. Detecting that the front panel diagnostic interrupt button has been pressed. c. Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action enabled. Table 20 shows behavior regarding NMI signal generation and event logging by the BMC. Table 20. NMI Signal Generation and Event Logging Causal Event Chassis Control command (pulse diagnostic interrupt) Front panel diagnostic interrupt button pressed Watchdog Timer pre-timeout expiration with NMI/diagnostic interrupt action Signal Generation X X X NMI (IA-32 Only) Front Panel Diag Interrupt Sensor Event Logging Support - X - 4.12 BMC Basic and Advanced Management Features The Intel® Server Board S2600JF product includes support for an upgrade module to support the advanced server management functionality. Table 21. Basic and Advanced Management Features Feature IPMI 2.0 Feature Support In-circuit BMC Firmware Update FRB 2 Chassis Intrusion Detection Fan Redundancy Monitoring Hot-Swap Fan Support Acoustic Management Diagnostic Beep Code Support Power State Retention ARP/DHCP Support PECI Thermal Management Support E-mail Alerting Embedded Web Server SSH Support Integrated KVM Integrated Remote Media Redirection Local Directory Access Protocol (LDAP) Intel® Intelligent Power Node Manager Support*** SMASH CLP Basic* X X X X X X X X X X X X X X X X X * Basic management features provided by Integrated BMC Advanced** X X X X X X X X X X X X X X X X X X X Revision 1.4 51 Intel order number G31608-005

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

Intel®
Server Board S2600JF TPS
Platform Management Functional Overview
Revision 1.4
Intel order number G31608-005
51
a. Receiving a
Chassis Control
command to pulse the diagnostic interrupt. This command
does not cause an event to be logged in the SEL.
b.
Detecting that the front panel diagnostic interrupt button has been pressed.
c.
Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action
enabled.
Table 20
shows behavior regarding NMI signal generation and event logging by the BMC.
Table 20. NMI Signal Generation and Event Logging
Causal Event
NMI (IA-32 Only)
Signal Generation
Front Panel Diag Interrupt Sensor Event Logging
Support
Chassis Control
command (pulse diagnostic
interrupt)
X
Front panel diagnostic interrupt button pressed
X
X
Watchdog Timer pre-timeout expiration with
NMI/diagnostic interrupt action
X
4.12
BMC Basic and Advanced Management Features
The Intel
®
Server Board S2600JF product includes support for an upgrade module to support
the advanced server management functionality.
Table 21. Basic and Advanced Management Features
Feature
Basic*
Advanced**
IPMI 2.0 Feature Support
X
X
In-circuit BMC Firmware Update
X
X
FRB 2
X
X
Chassis Intrusion Detection
X
X
Fan Redundancy Monitoring
X
X
Hot-Swap Fan Support
X
X
Acoustic Management
X
X
Diagnostic Beep Code Support
X
X
Power State Retention
X
X
ARP/DHCP Support
X
X
PECI Thermal Management Support
X
X
E-mail Alerting
X
X
Embedded Web Server
X
X
SSH Support
X
X
Integrated KVM
X
Integrated Remote Media Redirection
X
Local Directory Access Protocol (LDAP)
X
X
Intel
®
Intelligent Power Node Manager
Support***
X
X
SMASH CLP
X
X
* Basic management features provided by Integrated BMC