Intel SC5400 Product Specification - Page 66

External Memory Device

Page 66 highlights

Hot Swap Hard Disk Drive Bays Intel® Server Chassis SC5400 5U Kit TPS VSC410* Pin I/O Power Name Type Well P2_6 O 3.3V P2_7 O 3.3V P3_0 I/O 3.3V P3_1 I/O 3.3V. P3_2 I/O 3.3V P3_3 I/O 3.3V Programming Description Test Point Test Point Clock signal of SGPIO interface Load signal of SGPIO interface SDATAIN signal of SGPIO interface SDATAOUT signal of SGPIO interface System Function _N Reset State TP_LED_DRV10_FLT_ N TP_FM_DRV10_PRSN T_N SGPIO_CLK SGPIO_LOAD SGPIO_DATAOUT0 SGPIO_DATAOUT1 Initial Value Connection 6.1.3 External Memory Device The 4HDD and 6HDD passive SAS/SATA HSBP contains a non-volatile 8Mbit Serial SPI FLASH Memory for Boot and Run-Time/Configuration code storage. The device resides on the SPI interface of VSC410* controller. The Serial SPI Flash memory operates from the 3.3V rail. 6.1.4 LEDs The 4HDD and 6HDD passive SAS/SATA HSBP contain a green STATUS LED and amber FAULT LED for each of the six hard disk drives. The STATUS LED is driven by the SAS/SATA hard disk drive itself. The FAULT LED is driven by the VSC410* controller whenever a condition, as defined by the firmware, is detected. Status LED Green Amber on Table 43. LED Function Condition On Blink (0.5s on 0.5s off, 50% duty cycle of a 1s) Blink (1s on 1s off, 50% duty cycle of a 2s) On Blink Definition HDD Active Spin up/spin down(SAS HDD) Formating(SAS HDD) HDD Fail Rebuild Note: For SAS drives, Green LED will be on when drive is installed and ready. For SATA drives Green LED will be off when drive is installed and ready. 56 Revision: 1.0

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

Hot Swap Hard Disk Drive Bays
IntelĀ® Server Chassis SC5400 5U Kit TPS
56
Revision: 1.0
VSC410* Pin
Name
I/O
Type
Power
Well
Programming
Description
System Function
Reset
State
Initial
Value
Connection
_N
P2_6
O
3.3V
Test Point
TP_LED_DRV10_FLT_
N
P2_7
O
3.3V
Test Point
TP_FM_DRV10_PRSN
T_N
P3_0
I/O
3.3V
Clock signal of SGPIO
interface
SGPIO_CLK
P3_1
I/O
3.3V.
Load signal of SGPIO
interface
SGPIO_LOAD
P3_2
I/O
3.3V
SDATAIN signal of SGPIO
interface
SGPIO_DATAOUT0
P3_3
I/O
3.3V
SDATAOUT signal of
SGPIO interface
SGPIO_DATAOUT1
6.1.3
External Memory Device
The 4HDD and 6HDD passive SAS/SATA HSBP contains a non-volatile 8Mbit Serial SPI
FLASH Memory for Boot and Run-Time/Configuration code storage. The device resides on the
SPI interface of VSC410* controller.
The Serial SPI Flash memory operates from the 3.3V rail.
6.1.4
LEDs
The 4HDD and 6HDD passive SAS/SATA HSBP contain a green STATUS LED and amber
FAULT LED for each of the six hard disk drives. The STATUS LED is driven by the SAS/SATA
hard disk drive itself. The FAULT LED is driven by the VSC410* controller whenever a
condition, as defined by the firmware, is detected.
Table 43. LED Function
Status LED
Condition
Definition
On
HDD Active
Blink (0.5s on 0.5s off, 50% duty
cycle of a 1s)
Spin up/spin down(SAS HDD)
Green
Blink (1s on 1s off, 50% duty
cycle of a 2s)
Formating(SAS HDD)
Amber on
On
HDD Fail
Blink
Rebuild
Note:
For SAS drives, Green LED will be on when drive is installed and ready. For SATA drives Green LED will be off when
drive is installed and ready.