Intel SR1425BK1 Product Specification - Page 29

Hot-Swap SCSI Backplane

Page 29 highlights

Intel® Server Chassis SC1400UP / Intel® Server Platform SR1425BK1-E Figure 18. Drive Tray with Drive Blank 3.3 Hot-Swap SCSI Backplane The SC1400UP SCSI hot-swap backplane (HSBP) supports the following feature set: ƒ QLogic® GEM359 enclosure management controller o External non-volatile Flash ROM o Two I2C interfaces o Low Voltage Differential (LVD) SCSI Interface o SCSI-3 compatible o Compliance with SCSI Accessed Fault Tolerant Enclosures (SAF-TE) specification, version 1.00 and addendum o Compliance with Intelligent Platform Management Interface (IPMI) ƒ Support for up to three U320 LVD SCSI Drives o Onboard LVD SCSI Termination - SPI-4 compatible ƒ Temperature Sensor ƒ Hard Drive Status LEDs ƒ FRU EEPROM ƒ One 2x3-pin Power Connector ƒ IDE Connector provided for Slim-line CDROM or DVD support ƒ Floppy Connector provided for Slim-line floppy support ƒ Control Panel Connector 3.3.1 Hot-Swap SCSI Backplane Board Layout The following diagram shows the layout of major components and connectors of the board. Revision 1.0 - 29 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

Intel® Server Chassis SC1400UP / Intel® Server Platform SR1425BK1-E
Revision 1.0
- 29 -
Figure 18. Drive Tray with Drive Blank
3.3
Hot-Swap SCSI Backplane
The SC1400UP SCSI hot-swap backplane (HSBP) supports the following feature set:
QLogic
®
GEM359 enclosure management controller
o
External non-volatile Flash ROM
o
Two I
2
C interfaces
o
Low Voltage Differential (LVD) SCSI Interface
o
SCSI-3 compatible
o
Compliance with SCSI Accessed Fault Tolerant Enclosures (SAF-TE) specification,
version 1.00 and addendum
o
Compliance with Intelligent Platform Management Interface (IPMI)
Support for up to three U320 LVD SCSI Drives
o
Onboard LVD SCSI Termination – SPI-4 compatible
Temperature Sensor
Hard Drive Status LEDs
FRU EEPROM
One 2x3-pin Power Connector
IDE Connector provided for Slim-line CDROM or DVD support
Floppy Connector provided for Slim-line floppy support
Control Panel Connector
3.3.1
Hot-Swap SCSI Backplane Board Layout
The following diagram shows the layout of major components and connectors of the board.