Intel SR1630BC Service Guide

Intel SR1630BC - Server System - 0 MB RAM Manual

Intel SR1630BC manual content summary:

  • Intel SR1630BC | Service Guide - Page 1
    Intel® Server System SR1630BC Service Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number E53480-001
  • Intel SR1630BC | Service Guide - Page 2
    Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2008, Intel Corporation. All Rights Reserved ii Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 3
    Intel® Server System SR1630BC Service Guide iii
  • Intel SR1630BC | Service Guide - Page 4
    iv Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 5
    components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Server System SR1630BC. For the latest version of this manual, see http://support.intel.com/ support/motherboards/server/S5500BC. Manual Organization Chapter 1 provides a list
  • Intel SR1630BC | Service Guide - Page 6
    Toolkit 3.0 CD • Intel® System Management Software CD Note: You may need or want to purchase one or more of the following items for your server: • Processor and passive heat sink • Memory DIMMs • Hard drive • CD-ROM or DVD-ROM drive • RAID controller vi Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 7
    about which accessories, memory, processors, and third-party hardware were tested and can be used with your board, and for ordering information for Intel products, see: http://support.intel.com/support/motherboards/server/ S5500BC/compat.htm Intel® Server System SR1630BC Service Guide vii
  • Intel SR1630BC | Service Guide - Page 8
    viii Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 9
    in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit 3.0 CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie
  • Intel SR1630BC | Service Guide - Page 10
    http: //support. intel. com/support/motherboards/server/sb/C S -010770. htmϞⱘ,QWHO 6HUYHU%RDUGVDQG6HUYHU&KDVVLV6DIHW\,QIRUPDWLRQ˄lj,QWHO x Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 11
    the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System SR1630BC Service Guide xi
  • Intel SR1630BC | Service Guide - Page 12
    xii Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 13
    Control Panel 15 Bezels ...16 Standard Control Panel 15 Rear of Server System ...17 Peripheral Devices ...18 Hard Disk Drives...18 Slimline Optical Drive Carrier 19 Rack-Mounted Systems...19 Hardware Requirements...19 Processor ...19 Memory...20 Intel® Server System SR1630BC Service Guide xiii
  • Intel SR1630BC | Service Guide - Page 14
    -in Card 46 Removing a PCI Add-in Card 47 Removing and Installing the System Blowers 48 Replacing the System Blower 48 Replacing the Server Board 52 Removing the Server Board 52 Installing the Server Board 53 Replacing the Backup Battery 54 xiv Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 15
    Upgrade 63 Upgrading the BIOS ...64 Clearing the CMOS ...64 Resetting the Password ...65 Appendix A: Technical Reference 67 400-W Single Power Supply Input Voltages 67 400-W Single Power Supply Output Voltages 67 System Environmental Specifications 68 Appendix B: Intel® Server Issue Report Form
  • Intel SR1630BC | Service Guide - Page 16
    systéme 123 Avertissements sur le montage en rack 124 Décharges électrostatiques (ESD 125 Autres risques ...125 Périphériques laser 126 Español ...126 xvi Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 17
    cable de alimentación 128 Advertencias el acceso al sistema 129 Advertencias sobre el montaje en bastidor 130 Descarga electrostática (ESD 131 Otros riesgos ...131 Intel® Server System SR1630BC Service Guide xvii
  • Intel SR1630BC | Service Guide - Page 18
    xviii Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 19
    44 Figure 39. Removing the PCI Riser Assembly from the Server System 45 Figure 40. Installing the PCI Riser Assembly 46 Figure 41. Installing the PCI Riser Assembly from the Server System 47 Figure 42. Installing a PCI Card in a Riser Card 47 Intel® Server System SR1630BC Service Guide xix
  • Intel SR1630BC | Service Guide - Page 20
    the Power Supply into the Server System 57 Figure 53. Installing the Rack Handle 58 Figure 54. Removing the Rack Handle 59 Figure 55. CMOS Recovery Jumper 65 Figure 56. Password Recovery Jumper 66 Figure 57. Diagnostic LED Placement Diagram 75 xx Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 21
    of Tables Table 1. Server System References 1 Table 2. Intel® Server System SR1630BC Feature Summary 4 Table 3. NIC LED Descriptions 13 Table 4. Control Panel LED Functions 15 Table 5. Setup Menu Key Use 62 Table 6. 400-W Single Power Supply Output Voltages 67 Table 7. System Environmental
  • Intel SR1630BC | Service Guide - Page 22
    xxii Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 23
    System List can be found at: http://support.intel.com/support/motherboards/server/S5500BC/ Supported Processors can be found at: http://support.intel.com/support/motherboards/server/S5500BC/ Supported Memory can be found at: http://support.intel.com/support/motherboards/server/S5500BC/ Power
  • Intel SR1630BC | Service Guide - Page 24
    intel.com/support/motherboards/server/S5500BC/ Diagnostics: Platform Confidence Test (PCT) Found at: http://support.intel.com/support/motherboards/server/S5500BC/ and available on the Intel® Server Deployment Toolkit 3.0 CD that ships with your system. 2 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 25
    briefly describes the main features of the Intel® Server System SR1630BC. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system. Figure 1. Intel® Server System SR1630BC
  • Intel SR1630BC | Service Guide - Page 26
    95 W Thermal Design Power (TDP) One riser slot supporting one low-profile half-length PCI Express* 2.0 x8 add-in card Supports system fans On board ServerEngines* LL C Pilot II BMC controller • Integrated 2D video controller • 32 MB DDR2 667 MHz memory 4 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 27
    correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the following figures to determine the correct cable routing for a fixed drive system. Intel® Server System SR1630BC Service Guide 5
  • Intel SR1630BC | Service Guide - Page 28
    21 345 0 CPU 2 CPU 1 Optical Device HDD 0 HDD 1 AF003104 Figure 2. Cable Routing Drawing 6 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 29
    handles (two) B. Processor air duct C. System memory DIMM sockets D. PCI add-in card bracket E. Power supply F. CPU Heatsink (two) G. System blower fans (two) H. Hard drives (two) I. Control panel J. Slimline optical drive Figure 3. System Components Intel® Server System SR1630BC Service Guide 7
  • Intel SR1630BC | Service Guide - Page 30
    W. CPU 1 fan header Z. Intel® 5500 Chipset CC. System fan 1 header FF. SATA 0 X. CPU Power Connector AA. CPU Socket 2 DD. DIMM sockets off Processor 2 socket (Channel D, E) GG. SATA 1 Figure 4. Server Board Connector and Component Locations 8 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 31
    for normal operation. These pins should have a jumper in place for normal system operation.(Default) The main system BIOS will not boot with these pins jumpered. Note: The system boots from EFI-bootable recovery media with a recovery BIOS image. Intel® Server System SR1630BC Service Guide 9
  • Intel SR1630BC | Service Guide - Page 32
    Jumper Name J8B5: ME Force Update Pins 1-2 2-3 What happens at system reset... These pins should have a jumper in place for normal system operation (Default) ME force update model Figure 5. Configuration Jumper Location 10 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 33
    The 5-V STBY LED on the server board (see Figure 6) is illuminated (green) when AC power is applied. • Fan Fault LEDs on the server board (see Figure 6) help identify failed and failing fans. The fan fault LEDs turn on (amber) if there is a fan fault. Intel® Server System SR1630BC Service Guide 11
  • Intel SR1630BC | Service Guide - Page 34
    LEDs A. POST Code Diagnostic LEDs B. Status LED C. System ID LED D. HDD LED E. System Fan 3 Fault LED F. 5 VSB LED G. DIMM Fault LED H. System Fan 2 Fault LED I. CPU 1 Fan Fault LED J. CPU 2 Fan Fault LED K. System Fan 1 Fault LED L. DIMM Fault LED 12 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 35
    network connection Network connection in place Transmit/receive activity 10 Mbps connection (if left LED is on or blinking) 100 Mbps connection 1000 Mbps connection Intel® Server System SR1630BC Service Guide 13
  • Intel SR1630BC | Service Guide - Page 36
    on the SATA Key connector that is located at the right side of the server board. For information on how to install the Intel® RAID Activation Key AXXRAKSW5 accessory to enable RAID 5, see the documentation that is included with the accessory kit. 14 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 37
    4. Control Panel LED Functions LED NIC1/ NIC2 Activity Power / Sleep (on standby power) Color Green Green Green Off On Blink On Blink Off State Description NIC Link/no access LAN access Power on Sleep / ACPI S4 state Power Off / ACPI S4 state Intel® Server System SR1630BC Service Guide 15
  • Intel SR1630BC | Service Guide - Page 38
    provides a lock to secure the hard drive and optical drive area. For instructions on installing the front bezel, see "Installing the Front Bezel". The order number for the bezel is: • AHJBEZBLACK: Black bezel for use with the standard control panel. 16 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 39
    A. AC Power Connector B. Serial Port A C. Video Connector D. NIC 1 Connector (10 / 100 / 1000 Mb) E. NIC 2 Connector (10 / 100 / 1000 Mb) F. USB Ports 6 and 7 G. USB Ports 8 and 9 H. PCI Express* Slot Figure 9. Server System I/O Connector Locations Intel® Server System SR1630BC Service Guide 17
  • Intel SR1630BC | Service Guide - Page 40
    Figure 10. Optional Peripherals Hard Disk Drives The server system ships with two fixed drive carriers for installing two Serial ATA (SATA) fixed drives. For instructions on installing hard drives, see "Installing and Removing a Fixed Hard Drive". 18 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 41
    System SR1630BC supports one or two Intel® Xeon® Processor 5500 series with 95W Thermal Design Power (TDP) or less and with a max data transfer rate of 6.4 GT/s. For a complete list of supported processors, see the links under "Server System References". Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 42
    server board requires DDR3 DIMMs within a channel to be populated starting with the DIMM farthest from the processor. See the following figure (Figure 12). For a complete list of supported memory DIMMs, see the links under "Server System References". 20 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 43
    Performance Mode preferred for Intel® Xeon® Processor 5500 series based platforms. All three channels may Mirroring The spare mode is not supported by Intel® Server System SR1630BC. With memory mirroring, the system maintains two copies of all data Intel® Server System SR1630BC Service Guide 21
  • Intel SR1630BC | Service Guide - Page 44
    server board. See the documentation included with your server chassis for additional drive information and drive installation instructions. Note: The Intel® Remote Management Module 3 will not be supported in the Intel® Server System SR1630BC system. 22 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 45
    attention to the "Safety Information" at the beginning of this manual. Note: Whenever you service the system, you must first power down the server and unplug all peripheral devices and the AC power cord. Tools and Supplies Needed • Phillips* (cross head) screwdrivers (#1 bit and #2 bit) • Needle
  • Intel SR1630BC | Service Guide - Page 46
    Front Bezel At each end of the bezel, line up the center notch on the bezel with the center guide on the rack handles and push the bezel onto the front of the server system until it clicks into place. AF002891 Figure 14. Installing the Front Bezel 24 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 47
    it stops and lift the cover upward to remove it (see letter "B"). Figure 15. Removing the Server System Cover Installing the System Cover 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information" on page -ix. Intel® Server System SR1630BC Service Guide 25
  • Intel SR1630BC | Service Guide - Page 48
    Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. Lift the processor air duct from its location behind the two system blower fans. 26 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 49
    the air duct into place; insert the two hooks at the front of the processor air duct into the corresponding slots on the bracket behind the two system blower fans. Use caution not to pinch or disengage cables that may be near or under the air duct. Intel® Server System SR1630BC Service Guide 27
  • Intel SR1630BC | Service Guide - Page 50
    beginning of this book. 2. Turn off all peripheral devices connected to the server. 3. Turn off the server. 4. Disconnect the AC power cord from the server. 5. Remove the cover from the server and locate the DIMM sockets (see "Installing the Memory"). 28 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 51
    AC power cord from the server. 4. Remove the server's cover. 5. Gently spread the retaining clips at each end of the socket. The DIMM lifts from the socket. 6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 52
    7. Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets. 8. Replace the server's cover and reconnect the AC power cord. 30 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 53
    server chassis for instructions on removing the server's cover. 5. Locate the processor socket and open the socket lever (see Figure 20). Figure 20. Lifting the Load Lever 6. Open the load plate (see letter "A" in Figure 20 and letter "B" in Figure 21). Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 54
    Plate 7. Remove the socket protective cover (see Figure 22). Figure 22. Remove the Socket Protective Cover 8. Take the processor out of the box and remove the protective shipping cover (Figure 23). Figure 23. Remove the Processor Protective Cover 32 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 55
    cutouts to match the two socket pins, and then insert the processor into the socket as shown in Figure 24. Figure 24. Installing the Processor 10. Close the load plate (see the letter "A" in assist in package orientation and alignment with the socket: Intel® Server System SR1630BC Service Guide 33
  • Intel SR1630BC | Service Guide - Page 56
    according to the white-circled numbers (see Figure 27). 5. Securely re-tighten each fastener again in the same order as performed in Step 4. 6. Attach fan power cable to server board as shown. 34 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 57
    processor. 8. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force the heat sink from the processor. Doing so could damage the processor. 9. Lift the processor lever. 10. Raise the CPU load plate. Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 58
    , turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. You can install up to two fixed SATA drives in the Intel® Server System SR1630BC Service Guide. See "Server System References" for a link to a list of supported hardware. Installing and
  • Intel SR1630BC | Service Guide - Page 59
    Figure 28. Locating Drive Positions 2. HDD1 location only: Slide the power cables from the cable clip that is located on the top of the hard drive carrier later to reinstall the drive assembly. Lift the drive carrier from the chassis (see letter "B"). Intel® Server System SR1630BC Service Guide 37
  • Intel SR1630BC | Service Guide - Page 60
    The data and power connectors must be positioned so they are accessible through the cut-out, as shown by letter "B". Use the four screws provided to attach the drive to the carrier (see letter "C"). Figure 30. Installing Drive into the Drive Carrier 38 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 61
    drives. The cables are labeled at each end. 9. Connect the power cables to the drive(s): a. If a drive is installed in the HDD1 carrier, attach the connector on the daisy chain power cable that is closest to the power supply to the HDD1 connector. Intel® Server System SR1630BC Service Guide 39
  • Intel SR1630BC | Service Guide - Page 62
    on the daisy chain power cable to the HDD0 power connector. Figure 32. Connecting Hard Driver Power and Data Cables Removing a Fixed Hard Disk Drive 1. Disconnect the power and data cables from the drive carrier from the chassis (see letter "B"). 40 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 63
    of the system. Installing or Removing a Slimline Optical Drive Caution: Slimline optical drives are NOT hot-swappable. Before removing or replacing the drive, you must first take the server out of service, turn off all peripheral devices connected to Intel® Server System SR1630BC Service Guide 41
  • Intel SR1630BC | Service Guide - Page 64
    carrier from the server system (see letter "B"). oving Drive Blank from Drive Carrier Figure 34. Removing the Knockout in Bezel for Optical Opening 2. Attach the brackets to the optical drive using the four screws as shown in the following figure. 42 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 65
    cable to the optical drive and to the IDE connector on the server board.When the black drive carrier lever begins to close by itself, push on it to lock the drive assembly into place. Figure 36. Installing the Optical Drive into the Server System Intel® Server System SR1630BC Service Guide 43
  • Intel SR1630BC | Service Guide - Page 66
    drive assembly out of the chassis. C D B A AF002996 Figure 37. Removing the Slimline Optical Drive Assembly from the Server System 3. Remove the four screws from the brackets. Figure 38. Removing the Brackets from the Slimline Optical Drive Assembly 44 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 67
    Riser Assembly from the Server System Installing the PCI Riser Assembly 1. Lower the riser assembly into place (see letter "A"). 2. Align the two hooks in the riser assembly with the matching slots at the back of the server system (see letter "B"). Intel® Server System SR1630BC Service Guide 45
  • Intel SR1630BC | Service Guide - Page 68
    After removing the PCI riser assembly from the server system, remove the screw that attaches the PCI bracket shield to the rear of the chassis to remove the shield. Retain the screw. 2. Insert the PCI card edge connector in the slot on the PCI riser. 46 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 69
    1. Remove the screw holding the add-in card in place (see letter "A"). 2. Remove the PCI add-in card from the riser card connector (see letter "B"). Intel® Server System SR1630BC Service Guide 47
  • Intel SR1630BC | Service Guide - Page 70
    power supply fails, you must replace the power supply. Use the following steps to replace a system blowers or the PCI cooling fan. Replacing the System Blower 1. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct". 48 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 71
    them later (see letter "A" in the following figure). 4. Remove the fan cable from beneath the clip at the front of the fan bracket (see letter "B"). Intel® Server System SR1630BC Service Guide 49
  • Intel SR1630BC | Service Guide - Page 72
    disk drive brackets (see letter "C"). Figure 45. Removing the Blower Bracket from the Server System 6. Turn the bracket over and remove the two screws that attach the failed fan letter "B"). Figure 46. Removing the System Blowers from the Bracket 50 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 73
    bracket. 10. Secure the blower assembly to the system using the two screws you removed previously. 11. Connect the blower cables to the server board. See letters "A" and "B" in the following figure. Figure 47. Connecting the System Blower Cables Intel® Server System SR1630BC Service Guide 51
  • Intel SR1630BC | Service Guide - Page 74
    the seven screws from the server board (see letter "A") and lift the server board from the server system (see letter "B"). Figure 48. Removing the Server Board 8. Install the replacement server board. See "Installing the Server Board" on page -53. 52 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 75
    power supply to the server board. 4. Re-connect the PCI Fan and blower cables. 5. Re-connect all SATA cables to the server board. 6. Install the PCI riser assembly. 7. Install the memory, processor heat sinks, and processors. 8. Install the CPU air duct and air baffle. Intel® Server System SR1630BC
  • Intel SR1630BC | Service Guide - Page 76
    power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service . Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. 54 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 77
    power button, and unplug the AC power cord from the system or wall outlet. Removing the Power Supply You can replace the power supply if it fails or if one of the fans integrated into it fails. To replace the power supply, use the following instructions. Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 78
    power supply by sliding it out (see letter "D"). A B C D A C AF002912 Figure 51. Removing the Power Supply from the Server System Installing the Power Supply 1. Insert the replacement power supply by first engaging the back panel (see letter "A"). 56 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 79
    the power at the rear of the chassis (see letter "D"). Installing and Removing the Rack Handles Installing the Rack Handles 1. Align the rack handle with the holes on the side of the server system and attach the rack handle with the two screws. Intel® Server System SR1630BC Service Guide 57
  • Intel SR1630BC | Service Guide - Page 80
    Figure 53. Installing the Rack Handle 2. Repeat step 1 on the opposite side of the server. 58 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 81
    Removing the Rack Handles 1. Remove the two screws holding the rack handle in place, and remove the rack handle from the server system. Figure 54. Removing the Rack Handle Intel® Server System SR1630BC Service Guide 59
  • Intel SR1630BC | Service Guide - Page 82
    60 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 83
    Setup Utility options, which is used to change server configuration defaults. You can run the BIOS Setup with or without an operating system being present. See "Server System References" for a link to the Intel® Server Board S1630BC Technical Product Specification where you can find details about
  • Intel SR1630BC | Service Guide - Page 84
    "Setup Menu Key Use" describes the keyboard commands you can use in the BIOS Setup menus. Table 5. Setup Menu Key Use Key to Press Description Left and right arrows they were before was pressed without affecting any existing field values. 62 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 85
    and press when you see the message: Press Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You need these settings to configure your server at the end of the procedure. Intel® Server System SR1630BC Service Guide 63
  • Intel SR1630BC | Service Guide - Page 86
    on the server board. 1. Power down the system; do not disconnect the AC power. 2. Open the server. 3. Move the jumper from the normal operation position, CMOS Clear by MBX, at pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3. 64 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 87
    the server board. 1. Power down the system and disconnect the AC power. 2. Open the server chassis. 3. Move the jumper from the normal operation position, Password Clear Protect, at pins 1 and 2 to the Password Clear Erase position, covering pins 2 and 3. Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 88
    disconnect the AC power. 6. Return the Password Reset jumper to the Password Clear Protect position, covering pins 1 and 2. Reconnect AC power and power up the server. 7. The password is now cleared and you can reset it by going into the BIOS setup. 66 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 89
    Power Supply Output Voltages +3.3 V +5 V +12 V1 +12 V2 -12 V +5 VSB Voltage 15 A 10 A 24 A 8A 0.5 A 3.0 A Maximum Continuous 1. Maximum continuous total DC output power should not exceed 400 W. 2. Peak total DC output power should not exceed 450 W. 3. Peak power and current loading is supported
  • Intel SR1630BC | Service Guide - Page 90
    Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 +/- 2 degrees C). +/-15 kV except I/O port +/-8 KV, per Intel Environmental Test Specification. *The system requires the may cause improper operation of the product. 68 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 91
    . See the last page for space to include a detailed problem description Board / Chassis Information Baseboard Revision - PBA Baseboard Serial Number CPU1 Speed/Stepping/Spec CPU2 Speed/Stepping/Spec System BIOS Version HSC Firmware Version Chassis Model Intel® Server Chassis SC5650DP
  • Intel SR1630BC | Service Guide - Page 92
    Vendor / part number DIMM D2 MB and Vendor / part number DIMM E1 MB and Vendor / part number DIMM E2 MB and Vendor / part number Operating System Information Operating System Version Service Pack 70 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 93
    box below as applicable, and provide the requested information: Peripheral or Peripheral Description, Driver Revision, IRQ #, I/O Base Address, and FW Peripheral PCI Express* Gen2 Driver Revision IRQ I/O Base Address FW Revision # Revision #NIC Intel® Server System SR1630BC Service Guide 71
  • Intel SR1630BC | Service Guide - Page 94
    Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done 72 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 95
    Intel® Server System SR1630BC Service Guide 73
  • Intel SR1630BC | Service Guide - Page 96
    74 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 97
    a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board. To assist in troubleshooting a system hang during
  • Intel SR1630BC | Service Guide - Page 98
    ) Host processor cache initialization (including AP) Starting application processor initialization SMM initialization Selection of Processor with least feature use as Boot Strap Processor Switch an AP processor to become the new Boot Strap Processor 76 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 99
    X O X X BIOS cannot communicate with DIMM system halted) O X O O Memory test failed (system halted) O O X X Unsupported or invalid DIMM configuration (system halted) O O X O Unsupported or invalid DIMM configuration (system halted) Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 100
    X O O 0xB4h O X O O O X O O DIMM with corrupted SPD data detected (system halted) X X X X QPI Initialization X X X O QPI Initialization X X O X QPI X X Memory Initialization of Integrated Memory Controller 78 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 101
    O X O O O O X O Memory Initialization of Integrated Memory Controller O X O O O O O X Memory Initialization of Integrated Memory Controller O X O O O O O O Memory Initialization of Integrated Memory Controller Intel® Server System SR1630BC Service Guide 79
  • Intel SR1630BC | Service Guide - Page 102
    if supported by ATA device O O X O Reserved for ATA O O O X Resetting SMBUS O O O O Reserved for SMBUS X X X O Initializing I/O Controller Hub X X O O Initializing Super I/O X X X X Resetting the video controller (VGA) 80 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 103
    O X X O X X O X Reserved for mouse Serial Port 0xA8h O X O X O X X X Resetting the serial port 0xA9h O X O X O X X O Disabling the serial port 0xAAh O X O X O X O X Detecting the presence of the serial port Intel® Server System SR1630BC Service Guide 81
  • Intel SR1630BC | Service Guide - Page 104
    Selection phase (BDS) X X X O Return to last good boot device X X O X Set up boot device selection policy X X O O Connect boot device controller X O X X Attempt flash update boot mode 82 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 105
    X O X X X Checking password 0xE9h O O O X O X X O Entering BIOS setup 0xEAh O O O X O O X X Flash Update 0xEBh O O O X O O X O Legacy Option ROM Initialization 0xECh O O O X O X X X DXE Drivers initialized Intel® Server System SR1630BC Service Guide 83
  • Intel SR1630BC | Service Guide - Page 106
    system has requested the system to reset (ResetSystem () has been called) 0xFBh O O O O O X O X Entering System Management Mode 0xFCh O O O O O O X X Update Processor X X O O O O O X No crisis recovery capsule detected 84 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 107
    0x3Fh Table 10. Diagnostic LED POST Code Decoder X X O O O O O O Crisis recovery capsule failed integrity check of capsule descriptors Intel® Server System SR1630BC Service Guide 85
  • Intel SR1630BC | Service Guide - Page 108
    86 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 109
    .intel.com/support/motherboards/server This web page provides 24x7 support when you need it to get the latest and most complete technical support information on all Intel Enterprise Server and Storage Platforms. Information available at the support site includes: - Latest BIOS, firmware, drivers
  • Intel SR1630BC | Service Guide - Page 110
    88 Intel® Server System SR1600UR Service Guide
  • Intel SR1630BC | Service Guide - Page 111
    assembly instructions in this guide to the server system, power supply, and other modules have passed EMC testing using a server board server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel
  • Intel SR1630BC | Service Guide - Page 112
    (Australia) • MED Declaration of Conformity (New Zealand) • BSMI Declaration (Taiwan) • RRL Certification (Korea) • GOST - Listed on one System License (Russia) • Belarus - Listed on one System License (Belarus) • Ecology Declaration (International) 90 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 113
    Product Regulatory Compliance References The following table references Server Chassis Compliance and markings that may appear on the product. Markings (Safety) GB 9254 (Emissions) GB17625 (Harmonics) CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A Intel® Server System SR1630BC User's Guide 91
  • Intel SR1630BC | Service Guide - Page 114
    CB Certification IEC60950 CISPR 22 / CISPR 24 None Required Japan VCCI Certification Korea RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) 92 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 115
    Description Russia Ukraine Compliance Reference GOST-R Certification GOST R 2921691 (Emissions) GOST R 5062895 (Immunity) Ukraine Certification Compliance Reference Marking Example None Required Taiwan BSMI CNS13438 R33025 Intel® Server System SR1630BC User's Guide 93
  • Intel SR1630BC | Service Guide - Page 116
    related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However 94 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 117
    receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. Intel® Server System SR1630BC User's Guide 95
  • Intel SR1630BC | Service Guide - Page 118
    area of the product. Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel's product ecology compliance criteria. 96 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 119
    Code of Regulations, Title 22, Division 4.5; Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. None Required Intel® Server System SR1630BC User's Guide 97
  • Intel SR1630BC | Service Guide - Page 120
    Retail Packaging Only for Boxed Boards Compliance Reference Marking Example None Required. Intel Internal Specification International All materials, parts and subassemblies must not contain restricted to Retail Packaging Only for Boxed Boards 98 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 121
    two power supply cords before servicing. Simplified Chin e s e 2) Traditional Chin ese 2) German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung Intel® Server System
  • Intel SR1630BC | Service Guide - Page 122
    for the region in which it is sold. • Peripheral Storage Devices: must be a UL recognized or UL listed accessory and TUV or VDE licensed. Total server configuration is not to exceed the maximum loading conditions of the power supply. 100 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 123
    End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. Intel® Server System SR1630BC User's Guide 101
  • Intel SR1630BC | Service Guide - Page 124
    102 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 125
    Product by means of hardware and/or software; OR • REPLACE the Product with another Product; OR • REFUND the then-current value of the Product if Intel is unable to repair or replace the Product. If such Product is defective, transportation charges for the return of Product to buyer within the USA
  • Intel SR1630BC | Service Guide - Page 126
    causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration Service To obtain warranty service for this Product, you may contact Intel or your authorized distributor. 104 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 127
    :// www.intel.com/), call your local distributor or an Intel Customer Support representative. See "Getting Help" for telephone numbers. Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. Intel® Server System SR1630BC Service Guide 105
  • Intel SR1630BC | Service Guide - Page 128
    106 Intel® Server System SR1630BC Service Guide
  • Intel SR1630BC | Service Guide - Page 129
    : http://support.intel.com/support/motherboards/server/sb/cs-010770.htm English SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps: 1. Turn off all peripheral devices connected to the system. 2. Turn off the system by pressing the power button
  • Intel SR1630BC | Service Guide - Page 130
    -CD oder unter: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus
  • Intel SR1630BC | Service Guide - Page 131
    instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site: http://support.intel.com/support/motherboards/server/sb . Nous vous recommandons l'usage de gants de protection. Intel® Server System SR1630BC User's Guide 109
  • Intel SR1630BC | Service Guide - Page 132
    cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores. Resource CD http://support.intel.com/support/motherboards/server/sb/cs010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 110 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 133
    dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Intel® Server System SR1630BC User's Guide 111
  • Intel SR1630BC | Service Guide - Page 134
    112 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 135
    server should be integrated and serviced only by technically qualified persons. You must adhere to the guidelines in this guide and the assembly instructions in your server manuals instructions are not followed. Indicates hot components or surfaces. Intel® Server System SR1630BC User's Guide 113
  • Intel SR1630BC | Service Guide - Page 136
    outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Equipment Handling Practices Reduce the risk of for easier handling, remove any easily detachable components. 114 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 137
    Stromschlags hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin. Intel® Server System SR1630BC User's Guide 115
  • Intel SR1630BC | Service Guide - Page 138
    Geräte erzeugt werden. • In gewittergefährdeten Gebieten sollten Sie das System an einen Überspannungsschutz anschließen und bei einem Gewitter die Telekommunikationskabel zum lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. 116 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 139
    äts vom Stromnetz. Die Steckdose muß in der Nähe der Anlage angebracht und gut erreichbar sein. • Netzkabel müssen an eine ordnungsgemäß geerdete Steckdose angeschlossen sein. Intel® Server System SR1630BC User's Guide 117
  • Intel SR1630BC | Service Guide - Page 140
    , und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. 118 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 141
    Ausbau aus dem Server mit der Bauelementseite Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 142
    uniquement par des techniciens qualifiés. Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vérifier et maintenir la conformité avec et peuvent figurer sur le produit ou sur son emballage. 120 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 143
    du soleil et les radiateurs. • À l'écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. Intel® Server System SR1630BC User's Guide 121
  • Intel SR1630BC | Service Guide - Page 144
    ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin . L'intérieur de celui-ci est soumis à des 122 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 145
    Les cordons d'alimentation doivent répondre aux critères suivants : - Le cordon d'alimentation doit supporter une intensité supérieure à celle indiquée sur le produit. - Le cordon d'alimentation doit de télécommunication qui sont connectés au système. Intel® Server System SR1630BC User's Guide 123
  • Intel SR1630BC | Service Guide - Page 146
    le montage en rack Le rack doit être fixé à un support inamovible pour éviter qu'il ne bascule lors de l'extension d'un l'équipement. Le rack doit être installé conformément aux instructions du fabricant. Installez les équipements dans le rack en partant du Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 147
    système. • Vérifiez que les câbles, les cartes d'extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. Intel® Server System SR1630BC User's Guide 125
  • Intel SR1630BC | Service Guide - Page 148
    ceñirse a las directrices de esta guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de los graves si no se tiene en cuenta la ADVERTENCIA. 126 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 149
    correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. Intel® Server System SR1630BC User's Guide 127
  • Intel SR1630BC | Service Guide - Page 150
    de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precaució adquiera alguno cuyo uso esté aprobado en su país. 128 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 151
    fabricante para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. Intel® Server System SR1630BC User's Guide 129
  • Intel SR1630BC | Service Guide - Page 152
    el riesgo de descargas eléctricas, deberá instalar una conexión a tierra apropiada para el bastidor y para cada pieza del equipo instalada en el mismo. 130 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 153
    del equipo. Deseche las baterías respetando la normativa local. No intente recargar la batería. No intente desmontar, pinchar o causar cualquier otro desperfecto a una batería. Intel® Server System SR1630BC User's Guide 131
  • Intel SR1630BC | Service Guide - Page 154
    de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare 132 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 155
    简体中文 Intel Intel Intel Web UL 注意 警告 Intel® Server System SR1630BC User's Guide 133
  • Intel SR1630BC | Service Guide - Page 156
    ITE ITE 场地选择 5V 134 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 157
    Intel® Server System SR1630BC User's Guide 135
  • Intel SR1630BC | Service Guide - Page 158
    ESD) ESD ESD ESD ESD 136 Intel® Server System SR1630BC User's Guide
  • Intel SR1630BC | Service Guide - Page 159
    其他危险 替换电池 Intel® Server System SR1630BC User's Guide 137
  • Intel SR1630BC | Service Guide - Page 160
    138 Intel® Server System SR1630BC User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

Intel
®
Server System SR1630BC
Service Guide
A Guide for Technically Qualified Assemblers of Intel
®
Identified Subassemblies/
Products
Intel Order Number E53480-001