Intel SR1630GP Service Guide - Page 47
Updating the Integrated BMC, CMOS Recovery Jumper
UPC - 735858211871
View all Intel SR1630GP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
CMOS Clear 2 J1F5 3 Default CLEAR CMOS AF003182 Figure 12. CMOS Recovery Jumper 4. Wait five seconds. 5. Move the jumper back to default position, covering pins 1 and 2. 6. Close the server chassis. 7. Reconnect the AC power and power up the system. The CMOS is cleared and can be reset by going into the BIOS setup. Updating the Integrated BMC BMC Force Update 2 J1A2 3 Default Enabled AF003291 Figure 13. BMC Force Update Jumper When performing the standard Integrated BMC firmware update procedure, the update utility places the Integrated BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the Integrated BMC firmware update process fails (due to the Integrated BMC not being in the proper update state), the server Intel® Server System SR1630GP / SR1630HGP Service Guide 25