    Intel® RAID Controller SRCSASBB8I Hardware User's Guide Intel Order Number: E33166-001
  • Intel SRCSASBB8I | Hardware User Guide - Page 2
    in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2007-2008 by Intel Corporation. Portions Copyright 2005-2008 by LSI Logic Corporation. All rights reserved. ii Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 3
    is the primary hardware guide for the Intel® RAID Controller SRCSASBB8I, which can be used for SAS and SATA disk drives. It contains installation instructions and specifications. For details on how to configure the storage adapters, and for an overview of the software drivers, see the Software User
  • Intel SRCSASBB8I | Hardware User Guide - Page 4
    iv Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 5
    Support 2 Usability ...2 Redundancy and Error Handling 3 SAS/SATA Features of the 1078 Controller 4 Beep Codes ...5 Chapter 2, Intel® RAID Controller SRCSASBB8I Hardware Installation 7 Requirements ...7 Install the RAID Controller ...7 Configure the RAID Controller 10 Replacing a Controller
  • Intel SRCSASBB8I | Hardware User Guide - Page 6
    vi Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 7
    SCSI. The optional Intel® RAID Smart Battery AXXRSBBU6 provides cached data protection for the RAID controller, even during system created by the legacy ATA master-slave architecture, while maintaining compatibility with existing ATA firmware. Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 8
    list for your server board at http://support.intel.com/support/motherboards/server/. See also the tested hardware and operating system list for the Intel® RAID Controller SRCSASBB8I to make sure the RAID card supports your operating system. Usability • The card ships with both a standard and a low
  • Intel SRCSASBB8I | Hardware User Guide - Page 9
    out-of-band SES2. • Enclosure management support. • Fault indicators per drive. • controller and drive firmware, and SMART monitor. • Failures are logged in NVRAM, viewable from OS Event Log, Intel® RAID Web Console 2; CIM, LEDs, and via alarm. Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 10
    Redundancy through: - Configuration stored in nonvolatile RAM and on the drives (COD). - Hot-swap support. - Optional battery backup for cache memory. Controller provides fast or target (in a fail-over configuration) through an expander. 4 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 11
    , choose Disable Alarm. To enable alarm, choose Enable Alarm To disable alarm only until the next event or until next power cycle, choose Silence Alarm. Intel® RAID Controller SRCSASBB8I Hardware User's Guide 5
  • Intel SRCSASBB8I | Hardware User Guide - Page 12
    6 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 13
    Installation Requirements • The Intel® RAID Controller SRCSASBB8I, with the provided cables. • A host system with an available x8 or x16 PCI-Express* slot. • The Resource CD, which contains drivers and documentation. • SAS or SATA 3.0 hard drives. Note: Intel Corporation strongly recommends using an
  • Intel SRCSASBB8I | Hardware User Guide - Page 14
    instructions on installing an add-in card. See also the following figure. 85020-01 AF002634 Figure 2. Installing the Intel® RAID Controller SRCSASBB8I To prevent throughput problems, use the controller and cables are all properly attached. 8 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 15
    AF002631 Figure 3. Connecting Cables between the RAID Controller and Drives/Backplane 6. Install the server system cover and connect the power cords. See your server system documentation for instructions. Intel® RAID Controller SRCSASBB8I Hardware User's Guide 9
  • Intel SRCSASBB8I | Hardware User Guide - Page 16
    display the Intel® RAID Controller SRCSASBB8I number and firmware version. The numbering of the RAID controller follows the PCI slot scanning order used by the server board. 3. See the Quick Start User's Guide and the Software User's Guide for instructions to configure the RAID controller and to
  • Intel SRCSASBB8I | Hardware User Guide - Page 17
    LED signal support for controller to Mode 0 holds the I/O processor in reset for firmware recovery. • No jumper = Normal operational mode. • Jumper = Mode 0 for firmware recovery; requires a firmware recovery utility and firmware image file. Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 18
    Processor Operating voltage Card size Array interface to host SATA bus speed Serial port SAS controller SAS/SATA ports Physical and virtual drive support Cache Firmware Compatible devices Cabling Redundant configuration Enclosure management Enclosure support Intel® RAID Controller SRCSASBB8I LSI
  • Intel SRCSASBB8I | Hardware User Guide - Page 19
    on reboot Parity generation and checking, automatic consistency checking; patrol reads; activity and fault LEDs, alarm; multiple retries; logs in NVRAM, event log, CIM, Smart, Intel® RAID Web Console 2 Intel® RAID Controller SRCSASBB8I Hardware User's Guide 13
  • Intel SRCSASBB8I | Hardware User Guide - Page 20
    LFPM relative humidity non-condensing: 5%-90%. With battery 20-80% 10-90% condensing Safety Characteristics The Intel® RAID Controller SRCSASBB8I meets or exceeds the requirements of UL flammability are lower than the SELV 42.4 V limit. 14 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 21
    inserted properly. 6. Follow the instructions that came with your server system to remove the server cover. 7. Plug in and power on the system. The controller detects the RAID configuration from the configuration data on the drives (COD). Intel® RAID Controller SRCSASBB8I Hardware User's Guide 15
  • Intel SRCSASBB8I | Hardware User Guide - Page 22
    Follow the instructions that came with your server system to remove the server cover. 10. Plug in and power on the system. When you start the system, the controller detects the RAID configuration from the configuration data on the drives. 16 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 23
    peripherals from their power sources. Also disconnect any telephone or telecommunications lines from the computer. • Doing so reduces the potential for personal injury or shock. Intel® RAID Controller SRCSASBB8I Hardware User's Guide 17
  • Intel SRCSASBB8I | Hardware User Guide - Page 24
    You can do so by touching an unpainted metal surface, such as the metal around the card-slot openings at the back of the computer. • As you continue to work inside the computer . If possible, use antistatic floor pads and workbench pads. 18 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 25
    instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com\support\motherboards . 2. Check that cables, add-in cards, and other components are properly installed. Intel® RAID Controller SRCSASBB8I Hardware User's Guide 19
  • Intel SRCSASBB8I | Hardware User Guide - Page 26
    hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und -ServergehŠusen auf der Ressourcen-CD oder unter http:\\support.intel.com\support\motherboards\server\sb\cs-010770.htm System niemals ohne ordnungsgemäß montiertes Gehäuse ein. 20 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 27
    einige Platinen und Gehäuseteile scharfe Spitzen und Kanten aufweisen. Arbeiten an Platinen und Gehäuse sollten vorsichtig ausgeführt werden. Sie sollten Schutzhandschuhe tragen. Intel® RAID Controller SRCSASBB8I Hardware User's Guide 21
  • Intel SRCSASBB8I | Hardware User Guide - Page 28
    afin de prévenir tout accès non autorisé à l'intérieur du système. 5. Rebranchez tous les cordons d'alimentation c. a. et câbles externes au système. 22 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 29
    instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http:\\support.intel.com\support\motherboards\server sistema si se han extraído las tapas del chasis. Intel® RAID Controller SRCSASBB8I Hardware User's Guide 23
  • Intel SRCSASBB8I | Hardware User Guide - Page 30
    pannello anteriore non interrompe l'alimentazione in c.a. del sistema. Per interromperla, è necessario scollegare tutti i cavi di alimentazione in c.a. dalle prese a muro o dall'alimentazione di corrente. 24 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 31
    dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Intel® RAID Controller SRCSASBB8I Hardware User's Guide 25
  • Intel SRCSASBB8I | Hardware User Guide - Page 32
    26 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 33
    (EMC) & 1997-42 (EMI) (Korea) Product Regulatory Compliance Markings The RAID Controller Card is marked with the following compliance markings. Some marking information may be provided Mark (Europe) • VCCI Mark (Japan) • MIC Mark (Korea) Intel® RAID Controller SRCSASBB8I Hardware User's Guide 27
  • Intel SRCSASBB8I | Hardware User Guide - Page 34
    VCCI Marking (Class A) Japan CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A CANADA ICES-003 CLASS B CANADA NMB-003 CLASSE B VCCI Marking (Class B) Japan 28 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • Intel SRCSASBB8I | Hardware User Guide - Page 35
    , including interference that may cause undesired operation. Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124 not installed and used in accordance with the instructions, may cause harmful interference to radio communications Intel® RAID Controller SRCSASBB8I Hardware User's Guide 29
  • Intel SRCSASBB8I | Hardware User Guide - Page 36
    local Intel representative - Name of Certification Recipient: LSI Logic Corporation - Date of Manufacturer: Refer to date code on product - Manuation: LSI Logic Corporation Manufacturer/Nation / Refer to country of origin marked on product 30 Intel® RAID Controller SRCSASBB8I Hardware User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Intel
®
RAID Controller SRCSASBB8I
Hardware User’s Guide
Intel Order Number: E33166-001