Intermec IP30 IP30 and SR61B Battery (AB3 and AB19) Instructions

Intermec IP30 Manual

Intermec IP30 manual content summary:

  • Intermec IP30 | IP30 and SR61B Battery (AB3 and AB19) Instructions - Page 1
    Single Charger (with adapter P/N 871-233-001) For more information about IP30 or SR61B charging accessories, see the instructions that ship with the accessory. Important Recommendations yy Charge the battery immediately before use or within a couple of days of use. yy Use the Intermec battery AB3
  • Intermec IP30 | IP30 and SR61B Battery (AB3 and AB19) Instructions - Page 2
    away from children. Use only Intermec charger Models AC5, AC6, AC7 and AC8. Use of incorrect charger may present a risk of fire or explosion. CONTAINS LITHIUMION BATTERY. WASTE BATTERY MUST PROMPTLY BE RECYCLED OR DISPOSED OF PROPERLY. SEE INSTRUCTIONS. Proper Disposal of Waste Batteries Some of the
  • 1
  • 2

AB
3
| AB
19
IP30 & SR61B Battery Instructions
Using the AB3 and AB19 Batteries
These lithium-ion batteries are designed for use in these products:
y
Model IP30, IP30NI
y
Model SR61, SR61B, SR61BNI
Charging the Battery
Before using your IP30 or SR61B, you need to fully charge the battery.
Batteries can be charged after a partial discharge without affecting
the original battery capacity. A fully discharged battery charges in
approximately 3 to 4 hours.
You can charge the AB3 or AB19 battery with these accessories:
y
AC5 1-Bay Charger
y
AC6 2-Bay Charger
y
AC7 4-Bay Charger
y
AC8 8-Bay Charger
y
AC20 Quad Charger (with adapter P/N 871-233-001)
y
AD20 Single Charger (with adapter P/N 871-233-001)
For more information about IP30 or SR61B charging accessories, see
the instructions that ship with the accessory.
y
Only the AB19 has been qualified for use with IP30NI and
SR61BNI.
y
Discarded batteries may create a safety hazard. Before
disposal, cover the battery connector with electrical
insulating tape.
Specifications
Design and specifications are subject to change without notice.
Physical Specifications
Product:
Intermec Li-ion battery
(Model AB3 or AB19)
Length:
11.68 cm (4.6 in)
Width:
3.43 cm (1.35 in) at the widest part
Weight:
96.39 g (3.4 oz)
Capacity and Output Specifications
Maximum output:
x
4.2V
Nominal output:
x
3.7V
Capacity:
2400 mAH (8.9 Wh)
Temperature and Humidity Specifications
Operating temperature:
-20°C to 60°C (-4°F to 140°F)
Charging temperature for
desktop/wall mount 1-bay
charger:
0°C to 35°C (32°F to 95°F)
Charging temperature:
0°C to 45°C (32°F to 113°F)
Storage temperature:
-20°C to 60°C (-4°F to 140°F)
21°C (70°F recommended)
Relative humidity:
0% to 95% non-condensing
Important Recommendations
y
Charge the battery immediately before use or within a
couple of days of use.
y
Use the Intermec battery AB3 or AB19 only with an IP30 or R61B.
Use of
this battery in other devices could result in damage to the
device or battery.
y
The temperature range for charging batteries is 0°C to 35°C
(32°F to 95°F) for the 1-bay charger and 0°C to 45°C (32°F to
113°F) for the 2-bay, 4-bay, and 8-bay chargers. For maximum
battery life, charge batteries at 23°C (73°F).
y
Do not store the battery at temperatures above 60°C
(140°F), such as inside a car on a hot day or in direct
sunlight, as this may damage the battery.
y
Battery usage by children should be supervised.
y
Do not disassemble or open, crush, bend, deform, puncture, shred
or dispose of in fire.
y
Do not solder directly to the battery contacts.
y
Do not immerse the battery in water or get the battery
wet.
y
Do not short circuit the battery, and keep it away from
metallic items.
y
Do not drop the battery or apply mechanical shocks or
pressure to it.
y
Avoid dropping the battery or the IP30 or SR61B. If you suspect
that the battery or IP30 or SR61B is damaged, send it to an
Intermec service center for inspection.
y
Replace battery only with another AB3 or AB19 battery. This
battery has been tested in accordance with applicable safety
standards. Contact your Intermec sales representative or
distributor is this battery is no longer available.
Worldwide Headquarters
6001 36th Avenue West
Everett, Washington 98203
U.S.A.
tel
425.348.2600
fax 425.355.9551
www.intermec.com
© 2012 Intermec Technologies
Corporation. All rights reserved.
AB3/AB19 (IP30/SR61B) Battery Instructions
*943-018-005*
P/N 943-018-005
Caution: For the AB19 battery used with the IP30NI
and SR61BNI, battery replacement, charging, and
installation must only occur in areas known to be non-