JVC BR-DV600UA 45 pg user manual for BR-DV600U/E VTR (1130KB) - Page 13

Recording - video cassette recorder

Page 13 highlights

5 PREPARATION Built-in clock setting Time data is recorded in the sub code area of the tape during recording. In the Play mode, this data is read out and can be shown on the on-screen display or the counter display. [Reference] Clock data is retained for about 60 hours after the 6-hour power supply is used up (Operate On mode). MENU ADVANCE PRESET ADVANCE: Changes the value. PRESET: Enters the set value. HOLD: Start SHIFT: Digit shift SHIFT SHIFT HOLD SHIFT A. DUB SELECT SET CH 1/3 40 30 20 10 CH 2/4 32k 48k SLAVE AUD LOCK SP OVER AUTO OFF DEW 0 dB OVER SERVO RF PB NDF HOLD MONITOR OUTPUT COUNTER MENU L CH-1/2 CTL MIX MIX TC R CH-3/4 UB AUDIO TC: Time H M S F Time and date display UB: Date H M S F H M S F H M S F H M S F H M S F 5 Setting procedure The names of the operation buttons are shown above the buttons. 1 Set the tape counter display to the time display. Set the No. 516 menu switch to "CLOCK". ੬ See No. 516 on page 20. 2 Set the [COUNTER] switch to "TC" or "UB". • To set the time, set to "TC". The time display is shown in the tape counter. • To set the date, set to "UB". The date display is shown in the tape counter. 3 Engage the setting mode. Press the [HOLD] button. • Clock setting [ The hour digit starts to blink. • Date setting [ The month (U MODEL), day (E MODEL) digit starts to blink. 4 Change the value. Each time the [ADVANCE] button is pressed, the value of the blinking digit increases. While holding down the [SHIFT] button, press the [ADVANCE] button to reset the value as follows. • Clock setting: "00:00:00" • Date setting: "01:01:2000" 5 Shift the digit. Press the [SHIFT] button. • Clock setting: Each time the [SHIFT] button is pressed, the blinking cursor moves in the order of hours [ minutes [ seconds. • Date setting: Each time the [SHIFT] button is pressed, the blinking cursor moves in the order of month [ day [ year (U MODEL), day [month [ year (E MODEL). Repeat steps 4 to 5 to change the values for each digit. 6 Enter the set data. Press the [PRESET] button to enter the set data. 22 6 RECORDING [REC LEVEL] control CH-1/3 REC LEVEL VIDEO CASSETTE RECORDER BR-DV600U OPERATE ON/OFF EJECT CH-2/4 MENU ADVANCE PRESET SHIFT SHIFT HOLD SHIFT A. DUB PHONES SELECT SET MONITOR OUTPUT COUNTER L CH-1/2 CTL MIX MIX TC R CH-3/4 UB AUDIO CH 1/3 40 30 20 10 CH 2/4 OVER AUTO OFF DEW 0 dB OVER SERVO RF 32k 48k SLAVE PB NDF HOLD AUD LOCK SP MENU H M S F REC PLAY PAUSE REMOTE REW STOP FF LOCAL MIC [REC] button [PLAY] button [PAUSE] button [STOP] button Recording preparation Loading a cassette Check that the erasure prevention tab is set to allow recording. Insert the cassette in the cassette loading slot. Input video signal selection Select the input video signal with the No. 108 menu switch. LINE: Selects the composite video signals input to the [LINE IN] connector. Y/C: Selects the Y/C signals input to the [Y/C IN] connector. COMPONENT: Selects the component video signals input to the [COMPONENT IN] connector. IEEE 1394: Selects the digital video signals and the digital audio signals input to the [DV IN/OUT] connector. Audio sampling rate setting Select the audio sampling rate with the No. 245 menu switch. The number of usable audio channels is determined by the sampling frequency selected with the No. 245 menu switch. 5 32 kHz: 4 channels In normal recording, signals are recorded on CH1 and CH2. In the audio dubbing mode, signals are recorded on CH3 and CH4. 5 48 kHz: 2 channels Signals are recorded on CH1 and CH2. Audio dubbing is not possible. Adjust the audio recording level with the [REC LEVEL] control. Recording 1 Press the [PLAY] button while holding down the [REC] button. [Recording starts. 2 Press the [PAUSE] button to temporarily stop recording. To restart recording, press the [PLAY] button. To stop recording, press the [STOP] button. Notes: 5 If the unit remains in the Pause mode for more than 5 minutes, the Stop mode is automatically engaged to prevent the tape from being damaged. If tape remaining time is less than 3 minutes or the unit is being used in a low-temperature environment, the Stop mode is engaged within about 3 minutes. 5 When a tape recorded on this unit is played back on a consumer MiniDV VCR, the sound level may be low. 5 During recording, the upper section of the picture may be distorted or deflect. This is not a malfunction. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

22
Built-in clock setting
Time data is recorded in the sub code area of the tape during recording.
In the Play mode, this data is read out and can be
shown on the on-screen display or the counter display
.
5
PREPARATION
5
Setting procedure
The names of the operation buttons are shown above the buttons.
Set the tape counter displa
y to the time displa
y.
Set the No. 516 <DISPLA
Y SELECT> menu switch to
CLOCK
.
µ
See No. 516 <DISPLA
Y SELECT> on page 20.
Set the [COUNTER] switch to
TC
or
UB
.
To set the time, set to
TC
.
The time display is shown in the tape counter
.
To set the date, set to
UB
.
The date display is shown in the tape counter
.
Engage the setting mode.
Press the [HOLD] button.
Clock setting
[
The hour digit starts to blink.
Date setting
[
The
month (U MODEL), day (E MODEL)
digit starts
to blink.
Change the value.
Each time the [ADV
ANCE] button is pressed, the value of
the blinking digit increases.
While holding down the [SHIFT] button, press the
[ADVANCE] button to reset the value as follows.
Clock setting:
00:00:00
Date setting:
01:01:2000
Shift the digit.
Press the [SHIFT] button.
Clock setting: Each time the [SHIFT] button is pressed,
the blinking cursor moves in the order of hours
[
minutes
[
seconds.
Date setting: Each time the [SHIFT] button is pressed,
the blinking cursor moves in the order of
month
[
day
[
year (U MODEL), day
[
month
[
year (E MODEL).
Repeat steps 4 to 5 to change the values for each digit.
Enter the set data.
Press the [PRESET] button to enter the set data.
H
M
S
F
H
M
S
F
H
M
S
F
H
M
S
F
H
M
S
F
[Reference]
Clock data is retained for about 60 hours after the
6-hour power supply is used up (Operate On mode).
SP
SLAVE
SLAVE
SHIFT
SET
SELECT
SHIFT
MENU
HOLD
AUDIO
MONITOR
OUTPUT
COUNTER
SHIFT
A. DUB
ADVANCE
PRESET
L
CTL
TC
UB
CH-1/2
CH-3/4
R
MIX
MIX
MENU
OVER
OVER
H
M
S
F
AUD LOCK
32k
48k
PB
NDF
SERVO RF
DEW
AUTO OFF
HOLD
CH 2/4
CH 1/3
dB
40 30
20
10
0
Time and date displa
y
TC: Time
UB: Date
HOLD: Start
SHIFT:
Digit shift
ADVANCE: Changes the value.
PRESET:
Enters the set value.
23
PHONES
MIC
REMOTE
LOCAL
EJECT
OPERATE
REC LEVEL
CH-2/4
CH-1/3
SHIFT
SET
SELECT
SHIFT
MENU
HOLD
AUDIO
MONITOR
OUTPUT
COUNTER
SHIFT
A. DUB
ADVANCE
PRESET
L
CTL
TC
UB
CH-1/2
CH-3/4
R
MIX
MIX
REW
STOP
FF
REC
PLAY
PAUSE
ON/OFF
MENU
OVER
OVER
H
M
S
F
AUD LOCK
SP
32k
48k
SLAVE
PB
NDF
SERVO RF
DEW
AUTO OFF
HOLD
CH 2/4
CH 1/3
VIDEO CASSETTE RECORDER BR-DV600U
dB
40 30
20
10
0
6
RECORDING
Recording preparation
Loading a cassette
Check that the erasure prevention tab is set to allow
recording.
Insert the cassette in the cassette loading slot.
Input video signal selection
Select the input video signal with the No. 108 <VIDEO
INPUT SELECT> menu switch.
LINE:
Selects the composite video signals input to the
[LINE IN] connector
.
Y/C:
Selects the Y/C signals input to the [Y/C IN]
connector.
COMPONENT: Selects the component video signals input
to the [COMPONENT
IN] connector.
IEEE 1394: Selects the digital video signals and the digital
audio signals input to the [DV IN/OUT] connector
.
Audio sampling rate setting
Select the audio sampling rate with the No. 245 <SAMPLING
RATE> menu switch.
The number of usable audio channels is determined by the
sampling frequency selected with the No. 245 <SAMPLING
RATE> menu switch.
5
32 kHz: 4 channels
In normal recording, signals are recorded on CH1 and CH2.
In
the audio dubbing mode, signals are recorded on CH3 and CH4.
5
48 kHz: 2 channels
Signals are recorded on CH1 and CH2.
Audio dubbing is not
possible.
Adjust the audio recording level with the [REC LEVEL]
control.
[PLAY] button
[REC] button
[PAUSE] button
[STOP] button
Recording
Press the [PLAY] button while holding do
wn the
[REC] button.
[
Recording starts.
Press the [PAUSE] button to temporaril
y stop recording.
To restart recording, press the [PLA
Y] button.
To stop recording, press the [ST
OP] button.
Notes:
5
If the unit remains in the Pause mode for more than
5 minutes, the Stop mode is automatically engaged
to prevent the tape from being damaged.
If tape
remaining time is less than 3 minutes or the unit is
being used in a low-temperature environment, the
Stop mode is engaged within about 3 minutes.
5
When a tape recorded on this unit is played back on
a consumer MiniDV VCR, the sound level may be
low.
5
During recording, the upper section of the picture
may be distorted or deflect.
This is not a malfunc-
tion.
[REC LEVEL] control